Specifications

Troubleshooting
Step 2 Components
Troubleshooting
Step 2 Components
Faulty Controller
Thermocouple input
1 (30) 4 (20) 7 (11)
2 (31) 5 (21) 8 (32)
3 (13) 6 (33) 9 (12)
12 9 6 (15) 3
11 8 5 2
10 7 (18) 41 (14)
BACKSIDE - BOTTOM
BACKSIDE - TOP
Wires 11 & 12 - Input
Power 24 VAC
Wires 14 & 18 - Input
Detect Lower Valve Open Signal 24 VAC
Wires 14 & 15 - Input
Detect Upper Valve Open Signal 24 VAC
Wires 13 & 14 - Input
Detect Upper Ignition Module Power 24 VAC
Wires 30 & 33 - Output
Cook Light 24 VDC
Wires 30 & 31 - Output
Conveyor Motor Relay 24 VDC
Wires 30 & 32 - Output
Blower Motor Relay 24 VDC
Wires 14 & 20 - Output
Lower Ignition Module Call for Heat 24 VAC
Wires 14 & 21 - Output
Upper Ignition Module Call for Heat 24 VAC