SHCM-3168 SHOWER PANEL SHOWER PANEL INSTALLATION INSTRUCTIONS IMPORTANT DreamLine® reserves the right to alter, modify or redesign products at any time without prior notice. For the latest up-to-date technical drawings, manuals, warranty information or additional details please refer to your model’s web page on DreamLine.com SHCM-3168 c For more information about DreamLine® Shower Doors, Tub Doors & Enclosures, please visit DreamLine.com DreamLine SHCM-3168 Shower Panel manual Ver 1 Rev 1.
Table of Contents Section title Preparation Tools Required Detailed Diagram of Shower Panel Components Product Installation Steps Page # 03 04 05 06-09 Model Dimensions 10 Three Critical Steps 11 Shower Panel Functions Product Maintenance 12 ©2018 DreamLine. All Rights Reserved 13-14 DreamLine SHCM-3168 Shower Panel manual Ver 1 Rev 1.
Preparation 1. Prior to installation, examine all boxes and packages for shipping damage and compare the piece count with the packing slip. After opening all boxes, read this introduction carefully. Check that all of the necessary parts are included in the package by checking off the components on the “Parts List”. If the unit has been damaged, has a finishing defect, or has missing parts, please contact our customer support department within 3 business days of the delivery date.
Tools Required Drill bit Ø5/16" (8mm) Tubing Cutter Pencil Caulk and caulk gun Tape Measure Thread Seal Tape Safety Glasses Power Drill ©2018 DreamLine. All Rights Reserved Adjustable Wrench Level DreamLine SHCM-3168 Shower Panel manual Ver 1 Rev 1.
Detailed Diagram of Shower Panel Components Model SCHM-3168 SHCM-3168 Part # Description Qty. 01 Shower Panel Body 1 02 Shower Support Brackets 2 04 Shower Holder 1 05 Shower Wand Hose 1 06 Hand Shower 1 07 Shower Supply Hose 2 08 Screws M5 x 30 6 09 Wall Anchors 8mm / 5/16” 6 4 2 8 9 6 7 Table 1 Shower Panel Model Distance between support brackets 1 35" 33-11/16" 30-3/8" 32-5/16" 34-1/4" 26" 15-3/8" ©2018 DreamLine.
Product Installation Steps NOTE: TURN OFF ALL WATER SUPPLY TO THE SHOWER BEFORE BEGINNING THIS INSTALLATION 1. The stub-outs for the shower panel should be 1/2” copper pipe, angled down with 90-degree elbows, extending approximately 1-1/2” from the wall, with a 1/2” male threaded adapters on the ends. That will make attachment of the unit’s supply lines easier and allow the unit to sit flush against the wall.
3. Assemble the Handshower (#06), Shower Holder (#04) and the Shower Supply Hose (#07) according to the diagrams in Fig 3. Thread Seal Tape (View from rear of unit) Fig 3 4. Using a helper, place the unit against the shower wall at the desired position (over the two stub-outs) with the showerhead about 12”-18” above average head height (A). Plumb the unit with a level and mark the wall on the side of the unit as well as at the bottom of the unit. Remove the unit from the wall and carefully put it aside.
5. Measure the distance between the bottom edges of the two metal supports on the back of the shower panel (X). This dimension is also provided by the manufacturer on page 10 and in Table 1 on page 5 for comparison. Measure from the bottom of the unit to the bottom of the lower metal support (D). Using a level, draw two small lines on the wall to indicate the bottom edge of each metal support. (Fig 5) Mark bottom position of upper metal support on wall.
7. Using an assistant to hold the Shower Panel Body (#01), attach the flexible supply lines in the rear of the unit to the copper stub-outs using thread seal tape. Do not overtighten. Hang the unit on the installed Support Brackets (#02). Turn on the water supply and test the unit for leaks and functionality. (Fig 7) ©2018 DreamLine. All Rights Reserved SHCM-3168 Fig 7 DreamLine SHCM-3168 Shower Panel manual Ver 1 Rev 1.
Model Dimensions SHCM-3168 34-1/4” [870 mm] 59-1/2” [1511 mm] 59-1/2” [1511 mm] 7-1/16” (179 mm) Fig 8 Distance (X) between bottoms of metal supports 7-1/16” [179 mm] ©2018 DreamLine. All Rights Reserved 22-7/8” (581 mm) 2-7/8” (73 mm) DreamLine SHCM-3168 Shower Panel manual Ver 1 Rev 1.
Three Critical Steps input cold water (blue) input hot water (red) (View from back of unit) Fig 9 1) Be sure the cold water supply line is connected to the cold water end of the control valve (BLUE TAB) and the hot water supply line is connected to the hot water input on the control valve. (RED TAB). 2) Leave the backflow filters in the control valve connections when removing the blue and red tabs.
Shower Panel Functions NOTE: All of the functions shown may not be available for all shower panel models. 1. Top rain shower. (Figure 10) 3. Body shower. (Figure 12) 4. Hand shower. (Figure 13) DreamLine SHCM-3168 Shower Panel manual Ver 1 Rev 1.1 02/2018 Figure 11 Figure 12 ©2018 DreamLine. All Rights Reserved 2. Waterfall shower.
Product Maintenance Cleaning materials for faucets and showers: Cleaning Procedures: To avoid damage, it is necessary to use caution when cleaning. Damage caused by improper treatment is not covered under the warranty. Clean your faucets and shower products as necessary. Regular cleaning will prevent limescale buildup and water spotting. To remove limescale, use only products made specifically for that purpose. Always follow the manufacturer’s instructions. Follow the instructions.
Product Maintenance NOTE: If the water in your area contains rust, salt, lime or other minerals or contaminants, you’ll want to inspect your valve assembly regularly. The frequency for this will vary depending on the amount of contaminants in the water. Remove the cartridges and inspect them. Flush them with clean water, using a toothbrush when needed to remove any buildup. Striking the cartridge against the palm of your hand can also help loosen unwanted contaminants.
TEL: 866-731-2244 FAX: 866-857-3638 DREAMLINE.COM For more information on DreamLine® Shower Doors and Enclosures please visit DreamLine.com DreamLine SHCM-3168 Shower Panel manual Ver 1 Rev 1.1 02/2018 ©2018 DreamLine.