Owner's manual

M500 OPERATORS MANUAL Ch 8 - 1
CHAPTER 8
SAFETY CONSIDERATIONS
CAUTION - MAINS FUSE
TO REDUCE THE RISK OF FIRE REPLACE THE MAINS FUSE ONLY WITH THE SAME TYPE, WHICH MUST
BE A CLASS 3, 240 VOLT, SLO-BLO TYPE, RATED AT 80mA WHERE THE MAINS INPUT VOLTAGE SWITCH
IS SET TO 240 VOLTS AC. AND 160mA WHERE THE MAINS INPUT VOLTAGE IS 110 VOLTS AC. THE FUSE
BODY SIZE IS 20mm x 5mm.
For units with serial numbers 100 to 400. The fuse rating printed on the rear panel was incorrect. Fit a fuse
as rated above.
CAUTION - SERVICING
THIS UNIT CONTAINS NO USER SERVICEABLE PARTS. REFER ALL SERVICING TO QUALIFIED SERVICE
PERSONNEL. DO NOT PERFORM ANY SERVICING UNLESS YOU ARE QUALIFIED TO DO SO.
WARNING
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR
MOISTURE.
TECHNICAL SPECIFICATIONS
(Where applicable, measurements taken at +4dBu operating level)
KEY INPUT Balanced XLR at -10dBu or +4dBu signal levels.
INPUT IMPEDANCE 47K S
MAXIMUM INPUT LEVEL +17dB above reference.
OUTPUT IMPEDANCE 50 S (balanced)
MAXIMUM OUTPUT LEVEL +17dB above reference.
KEY INPUT ¼" jack at -10dBu or +4dBu signal levels.
SIDE CHAIN INPUT / OUTPUT ¼" stereo jack at -10dBu signal level only.
Ring Send; Tip Return.
BANDWIDTH 20Hz to 22KHz ±1dB
CROSSTALK -80dB @ 10KHz
NOISE AT UNITY GAIN with no effects assigned and 'OUTPUT' page selected.
Wideband 22Hz - 22KHz CCIR ARM IEC A Q-Pk CCIR
AV -84dB -92dB -92dB -95dB -81dB
RMS -82dB -91dB -91dB -94dB
DISTORTION 100Hz 1KHz 10KHz
Unity Gain, +4dBu input < 0.03% < 0.03% <0.03%
POWER REQUIREMENTS 115Volt or 230Volt at 50-60Hz, 25 Watts
FUSE RATING 80mA for 240Volt, 160mA for 120Volt
FUSE TYPE 20mm x 5mm, Class 3 Slo-Blo, 250Volt working
CASE SIZE 482mm (w) x 44mm (h) x 300mm (d)