User Manual

Status LED overview
Dräger X-zone 5500 75
Pump LED
(Indicates the pump status.)
Grouping LED
(Indicates the grouping status.)
Colour LED status Device mode Meaning
off
off
STANDBY mode Device is in STANDBY mode.
off
ON mode
No pump adaptor detected.
red/green Flow test required.
red Flow test running.
green
on
Flow test successful/pump is running.
red Flow error (e.g. due to lack of volume flow or no flow test).
Colour LED status Device hierarchy Meaning
off off
X-zone 5500
X-zone 5500 ungrouped
green X-zone 5500 ungrouped, can be added to a group.
red Several main devices found, X-zone 5500 cannot be grouped.
green on
Group device
X-zone 5500 is grouped.
green X-zone 5500 can be removed from a group.
red/green
on
Main device
X-zone 5500 is a main device.
red/green Group of the main device can be extended.
red/green
Group of the main device can be reduced.