Installation Instructions

EN
Dometic FreshWell3000 Installation
11
7.2 Making openings
See fig. 3
Mark the position and size of the openings using the template included in
the packaging (A and B).
See fig. 4
Drill out the corners (A).
Carefully cut out the opening on the roof using a keyhole saw or a similar
tool (B).
Make sure no electrical power cables are damaged.
Drill out a condensation water drainage opening with a diameter of
32 mm (C).
See fig. 5
Mark the position of the angle sections (A) and the fastening brackets (B).
7.3 Installing the fastening brackets and belts
See fig. 6
Fasten the four fastening brackets (A).
Pull the belts through the fastening brackets (B).
Install the drain pipes under the under-bench air conditioner (C).
Fasten the under-bench air conditioner with the belts (D).
7.4 Installing the angle section
See fig. 7
Fasten the under-bench air conditioner with the two angle sections an
three fastening screw for each as shown.
7.5 Installing the external grids
See fig. 8
Fasten the external grids as shown with the screws and washers included
in the supply.