7.2 Making openings
See fig. 3
➤ Mark the position and size of the openings using the template included in
the packaging (A and B).
See fig. 4
➤ Drill out the corners (A).
➤ Carefully cut out the opening on the roof using a keyhole saw or a similar
tool (B).
Make sure no electrical power cables are damaged.
➤ Drill out a condensation water drainage opening with a diameter of
32 mm (C).
See fig. 5
➤ Mark the position of the angle sections (A) and the fastening brackets (B).
7.3 Installing the fastening brackets and belts
See fig. 6
➤ Fasten the four fastening brackets (A).
➤ Pull the belts through the fastening brackets (B).
➤ Install the drain pipes under the under-bench air conditioner (C).
➤ Fasten the under-bench air conditioner with the belts (D).
7.4 Installing the angle section
See fig. 7
➤ Fasten the under-bench air conditioner with the two angle sections an
three fastening screw for each as shown.
7.5 Installing the external grids
See fig. 8
➤ Fasten the external grids as shown with the screws and washers included
in the supply.