User Manual

11
Fireplace Installation
In-wall Recessed
Installation - 100mm Deep
CAUTION: Two people may
be required for various steps of
this procedure.
1. Prepare a wall with a framed
opening of 118.1 cm wide x 42
cm high (Figure 4).
!
NOTE: The sizing has allowed
for 6.4mm around the fireplace
insert for ease of installation. This
fireplace does not require any
additional venting.
2. Choose your method of
supplying power to the unit:
Plug in (you may run the
power cord out of the framed
wall opening to an existing
outlet or install an outlet on
a nearby wall stud within the
wall).
Hard wire the replace.
!
NOTE: Hard wiring can be done
by removing the plug from the
factory tted cord and completing
the wiring according to National and
Local Elecrical Codes.
WARNING: Do not attempt to
wire your own new outlets or circuits.
To reduce the risk of re, electric
shock or injury to persons, always
use a licensed electrician.
Figure 5
Mounting
holes
Figure 4