Installation Sheet

12
www.dimplex.com
120V/240V WALL MOUNTED THERMOSTAT
!
NOTE: Before installing the unit complete the following:
1. Install main power connection with appropriate wiring - directly to the main power or through a wall switch.
2. Install a 2 conductor wire with ground (3 wires total) from the thermostat wall box to the junction box on the unit.
!
NOTE: Wiring of the thermostat must be completed prior to installing the unit.
!
NOTE: The following installation instructions are for a single pole thermostat.
1. Loosen the screw securing the junction box and remove the cover.
2. Remove the knockouts (if necessary) or use the provided cable clamp.
3. Pull out the three wires marked 1, 2, and G (red, red, and green).
4. Remove the wire connector and separate the wires marked 1 & 2.
5. Connect the 1 wire (red) from the unit to the Neutral (white) wire from the wall thermostat box by using a wire connector
(not supplied).
6. Connect the other end of the Neutral (white) wire from the thermostat wall box to the red wire from the wall thermostat.
7. Connect the 2 wire (red) from the unit to the black wire from the thermostat wall box by using a wire connector (not sup-
plied).
8. Connect the other end of the black wire from the thermostat wall box to the black wire from the wall thermostat.
9. Connect the Ground wire (green) from the unit to the Ground (green) wire from the thermostat wall box by using a wire
connector (not supplied).
10. Connect the other end of the Ground wire (green) to the thermostat wall box ground screw.
11. Ensure that all connections are tight.
12. Insert all the wiring of the wall mounted thermostat into the wall box.
13. Insert all the wiring back into the unit and secure with a cable clamp.
FIREPLACE JUNCTION BOX
WALL
THERMOSTAT
RED – 1
GROUND - G
RED – 2
BLACK
RED
GROUND
GROUND
2
1
GROUND
RED
BLACK
BLACK WIRE
WHITE WIRE
GROUND
SCREW
G
1
2
GROUND
G
!
NOTE: This only illustrates
thermostat connection, see
previous sections for main
power connection instruc-
tions.