Installation Guide

58
Appendix B: Reporting Codes
The following tables contain Contact ID and Auto-
matic SIA format reporting codes. For more informa-
tion on reporting code formats and notes about
individual reporting codes, see 2.3.11 Communicator
Reporting Formats on page 44 and 2.3.12
CommunicatorReporting Codes on page 47.
Contact ID
The first digit (in parentheses) will automatically be
sent by the control. The second two digits are pro-
grammed to indicate specific information about the
signal.
For example, if zone 1 is an entry/exit point, you could
program the event code as [34]. The central station
would receive the following:
*BURG - ENTRY/EXIT - 1
where the “1” indicates which zone went into alarm.
SIA Format - Level 2 (Hardcoded)
The SIA communication format used in this product
follows the level 2 specifications of the SIA Digital
Communication Standard - October 1997. This format
will send the Account Code along with its data trans-
mission. The transmission would look similar to the
following at the receiver:
N Ri01 BA 01
N = New Event
Ri01 = Area Identifier
BA = Burglary Alarm
01 = Zone 1
Section
#
Reporting Code Code Sent When...
Dialer
Directio
n*
Automati
c Contact
ID Codes
SIA Auto Rep
Codes**
[320] to
[323]
Zone Alarms zone goes into alarm A/R (1) 3A See Table 3
[324] to
[327]
Zone Restorals alarm condition has been restored A/R (1) 3A
[328] Duress Alarm duress code entered at keypad A/R (1) 21 HA-00
[328] Opening After Alarm system disarmed with alarm in memory A/R (4) A6 OR-00
[328] Recent Closing alarm occurs within two minutes of system arm-
ing
A/R (4) 59 CR-00
[328] Cross Zone (Police
Code) Alarm
two zones on the system go into alarm during
any given armed-to-armed period (incl. 24Hr
zones)
A/R (1) 4A BV-00
[329] [F] Key Alarm/Rest. Keypad fire alarm (alarm and restore reporting
codes sent together)
A/R (1) 15 FA-00/FH-00
[329] [A] Key Alarm/Rest. Keypad auxiliary alarm (alarm and restore report-
ing codes sent together)
A/R (1) AA MA-00/MH-00
[329] [P] Key Alarm/Rest. Keypad panic alarm (alarm and restore reporting
codes sent together)
A/R (1) 2A PA-00/PH-00
[330] to
[337]
Zone Tamper/Restoral zone is tampered / tamper condition restored T/R (1) 44 TA-ZZ/TR-ZZ
* A/R = alarms/restorals; T/R = tampers/restorals; O/C = openings/closings; MA/R = miscellaneous alarms/restorals;
T = test transmissions
** UU = user number (user01-42); ZZ = zone number (01-32)
***Program the “Fail to close” event code [(4)54] to report either closing or activity delinquency. Make sure your central station is
aware of the application of this reporting code.
****Zones are identified, panic pendants, wireless keys, and handheld keypads are not.