User`s manual

75
(5) Bluetooth
communications parameters
Items Parameters Defaults Refer to:
As a master
As a slave
Configure the scanner as master or slave
No slave/master configuration change
Section 2.2
Bluetooth
address
Local name
Connection target of scanner as master
Communications adapter
(BA11/10-RKU)
Section 2.2
Specification of connection target's address Connection target's address None Section 2.2
2 minutes
4 minutes
10 minutes
Timeout period for slave to wait for a
connection request
30 minutes
Section 8.1 (2)
Enable
Clear the transfer buffer when the
Bluetooth link is broken
Disable
Start operation
Bluetooth
interface
End operation
Section 2.1
(See Note 1.)
PIN code
1 to 8 digits alphanumeric characters
or symbols
1234
Enable
Security function
Disable
Unclassified device
Local Class of Device
Keyboard
(Note 1) The factory default is "End operation."
: Can be changed only with the configuration software.