Installation Guide

93488 Rev. A
5
Potential scald or thermal shock injury could result due to cross ow if outlet at the shower is
blocked or restricted (e.g., pause control on showerhead). Be sure to point showerhead away
from you when re-starting ow or install inlet check valves on both supply lines to prevent
possible injury.
6
Installation
4
Valve Trim Installation
F.
2
1
3
4
Diverter Handle Installation
Slide diverter handle (1) onto diverter cartridge
stem (2), ensure that handle aligns with
cartridge stem.
Install set screw (3) using an allen wrench,
place set screw cover (4) over set screw and
apply pressure until cover is properly seated.
D.
1
2
3
Temperature handle Installation
Secure temperature control knob (1) withscrew
(2). See next step (E) for securing temperature
control cover (3).
Snap temperature control cover over temperature
control knob by rst aligning smaller tab (1) on
cover with receiving slot (2) on temperature knob.
Swing larger tab (3) to engage with snap feature
(4). Note: If dis-assembly is required, reverse
this motion, disengaging larger tab (3) from snap
feature (4) rst.
E.
4
2
1
3