Instruction manual
13
TROUBLESHOOTING
Disconnect tool from air supply before performing any Service
Procedure.
SYMPTOM PROBLEMS SOLUTIONS
1. Air leak near top of Loose screws. Tighten screws.
tool or in trigger area. Worn or damaged Install Overhaul Kit.
o-rings or seals.
2. Tool does nothing or Inadequate air supply. Verify adequate air supply.
operates sluggishly. Inadequate lubrication. Put 5 or 6 drops of oil into air inlet.
Worn or damaged Install Overhaul Kit.
o-rings or seals.
3. Air leak near bottom Loose screws. Tighten screws.
of tool. Worn or damaged Install Overhaul Kit.
o-rings or bumper.
4. Tool jams frequently. Incorrect fasteners. Verify approved fasteners of
correct size.
Damaged fasteners. Replace w/undamaged fasteners.
Magazine or nose Tighten screws.
screws loose.
Magazine is dirty. Clean magazine.
Driver is worn or damaged. Install “DRIVER” Maintenance Kit.
5. Other. Contact a Porter-Cable/Delta
Service Facility.