Installation Sheet

Page 8
209257 Rev. A
Installation should be in accordance with local plumbing and electrical codes.
FLUSH ALL PIPES THOROUGHLY BEFORE INSTALLATION.
www.specselect.com
620TPxxx0 Hard Wire Operated Surface Mount Box #0
Fig. 19
Top Spacer
& Gasket
Washer
Nut
Spout
Bottom Spacer
Sensor
Module
Fig. 20
7" (178 mm)
Max.
13" (331 mm)
Max.
Tie
Wraps
Ļ
Fig. 23
STEP 1. FAUCET INSTALLATION
STEP 3. FLUSH SYSTEM
To flush supply line, assemble these components as shown (Fig. 21) and run water for one
minute. Shut off water supply. Attach aerator. NOTE: Do not connect supply to the solenoid
inlet until line is flushed directly out spout.
STEP 4. CONNECT WATER SUPPLY
Disassemble the components, reassemble the ones shown here (Fig. 22) supply line and adapter
to the bottom fitting on solenoid, polymer braided spout hose to the top fitting on solenoid. Use
plumber tape where indicated on adapter. Turn on water supply.
DO NOT SOLDER CONNECTIONS.
STEP 5. CONNECT PROXIMITY
®
SENSOR
Run the sensor wire out of the battery box through the box openings around the solenoid. Attach
the sensor module to the faucet shank with the clip. Ensure the clip does not contact any
material other than the faucet shank (Fig. 23).
STEP 6. PREPARE SINK AREA
Before connecting the power - clean off counter and remove all objects from the sink.
STEP 7a. CONNECT POWER
IMPORTANT: ENSURE THAT WATER SUPPLY IS ON BEFORE PROCEEDING. WHEN
POWER IS FIRST APPLIED TO THE DRIVER BOARD, THE INSTALLER MUST IMMEDIATELY
STEP BACK AT LEAST 3 FEET FROM THE PROXIMITY SPOUT IN ORDER TO ALLOW THE
UNIT TO PROPERLY CALIBRATE.
Install CSA and/or UL approved Class 2 transformer or equivalent in a convenient and appropriate
location. Do NOT install the transformer inside the control box. With the power off, connect the
24VAC supply from the transformer to the pair of white supply wires coming
from the hardwire converter. Refer to Fig. 24 and Fig. 25 for reference
wiring diagrams. Install the grounding kit assembly (061259A) per the
supplied instruction sheet for proper grounding with Conductive and Non-
Conductive sinks.
Turn on power supply for the transformer. 5 quick beeps 3 times will be
generated when power is first applied to the unit. At this stage, step back
at least 3 feet from the controller and spout in order to allow for proper
calibration. Do not secure the lid/cover until after calibration.
Bypass
Adapter
Braided
Polymer
Hose
INSTALLATION AND SET UP INSTRUCTIONS
Plumber
Tape
Fig. 21
Fig. 22
Braided
Polymer
Hose
063131A
3/8” Comp
Connect
Nut & Ferrile
Mount faucet to sink using the provided components in the following order - grey bottom spacer,
washer, lock nut (Fig. 19). NOTE: The black top spacer must be used at all times between
the spout and countertop, and the grey spacer must be used at all times between the
washer and deck. Ensure open side of bottom spacer faces up. The faucet and shank
must not touch any conductive surfaces (metal sink, screws, drainage). If cover plate is
being used, it must be between the top spacer and the deck. Ensure that gasket is sitting flat on
the deck and the faucet is centered on the gasket. Use the same procedure for installation of
optional 4” or 8” deck plate package (061269A or 061270A). Mount the faucet to the sink using
nut(s) and washer(s) provided. Do not overtighten the nut or reposition the faucet once installed,
otherwise damage to the gasket may result. Cutting or trimming of the gasket is not recom-
mended. NOTE: If the gasket is trimmed or not installed, then use clear silicone sealant
between the faucet and lavatory to prevent water from leaking beneath lavatory.
Mount surface mount box to wall under sink using the 4 supplied screws and anchors. Use 1/4”
drill for wall anchors. Be sure to install the box within the dimensions and orientation
provided so the hose and sensor cable will reach connections at faucet and surface mount
box. Refer to illustration (Fig. 20).
STEP 2. SURFACE MOUNT BOX INSTALLATION