Specification Sheet

Electronic Wallmount Faucet
1500T4 & 1501T4 Series
Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.
Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability.
DSP–1500T4 Rev. B
1500T & 1501T ELECTRONIC FAUCET OPTIONAL ACCESSORIES:
TRANSFORMERS:
060704A 110 to 24VAC Class II 20VA (Up to 5 Electronic Valves)
060771A 110 to 24VAC Class II 40VA (Up to 10 Electronic Valves)
060772A 110 to 24VAC Class II 100VA (Up to 25 Electronic Valves)
CORDS:
060690A 36" Cable Extension
GOOSENECK SPOUT ASSEMBLIES
Approvals:
CSA certified
Complies to ASME A112.18.1
ADA Compliant and meets
Handicapped Accessibility
Standard ASME A117.1 of less than
5 lbs. handle operating force.
IAPMO listed
Control Box Option 6 Mechanical Mixing
Valve CSA certified
Control Box Option 8 Thermostatic Mixing
Valve CSA certified and meets ASSE 1016,
1017, 1070
(Contact Delta Representative for State
and/or Local Approvals.)
U.S. Patent #6, 826, 455.
OPERATION:
Hands free (touchless) operation.
Water flows when sensor is activated.
Water flow stops upon de-activiation
of sensor.
Auto shut-off feature that is selectable
between 15 to 75 seconds.
Factory set to
45 seconds. Will reset once obstruction is
removed.
Adjustable sensing distance 76 to 381mm
(3" to 15") factory set to 229mm (9") (
+
/– 1.0”)
Low battery audible beep (for battery models
only) will activate after faucet shuts off when
approximately 1500 cycles remain.
NOTE: For optimum performance of this product,we recommend a
system pressure between 20 and 80 PSI static. This product will
operate up to a maximum of 125 PSI static per ANSI and CSA
requirements. However, we do not recommend pressures above
80 PSI. Thermal expansion or leaking pressure reducing valves may
require use of expansion tanks or relief valves to ensure your system
never exceeds its maximum intended pressure setting.
Note: Measurements may vary ± 6mm (0.25'')
“A” “C” “L
Spout/Outlet mm in. mm in. mm in.
Gooseneck-Standard (R5)
for Outlet #2 and 3 152 6 124 4.9 188 7.4
Gooseneck-Standard (R5)
for Outlet #7 152 6 117 4.6 196 7.7
Refer to www.specselect.com for individual models.
Product supplied as shown by solid lines. All items shown by dotted lines supplied by others.
OUTLET “D”
NO. mm in.
2 18 0.69
3 18 0.69
GOOSENECK SPOUT #6
FOR THICK WALLMOUNT INSTALLATION
GOOSENECK SPOUT #6
FOR THIN
WALLMOUNT INSTALLATION
1500T4670
TYPICAL INSTALLATION
FLOWRATE vs PRESSURE
No. 2 Laminar Flow Outlet
2.5
2
1.5
1
.5
00
0
1
2
3
4
5
6
7
8
9
10 20 30 40 50 60 70 80
Spout Outlets
No. 3 Aerator
Line Pressure (psig)
FLOW
(l/min.)
FLOW
(USGPM)
No. 7 Flow Control
Outlet Flowrates
1/8''(3mm)
Max.
Wall Thickness
12.7mm - 50.8mm
(.50 - 2.0")
32mm (1.25") Dia.
Hole Required
1/4" NPT Pipe
(5" long)
3/8" (9.5mm)
Compression
Connection
102mm
(4")
102mm
(4")
29mm
(1.125") Dia.
Hole Required
3/8" (9.5mm)
Compression
Connection
3/8" (9.5mm)
Compression
Adaptor
20" Hose
Supplied
Tempered Water
By Others
90º Elbow
Integral
Sensor
TECK
®
COMMERCIAL
HYDRO POWER
Add suffix “-HP” to Product
Number for Hydro Power
.
See DSP-HP for detailed
specification. Available on
Battery Powered #0 Control Box
and #2, 3, 7 outlets only.
HARDWIRE WITH
BATTERY BACKUP
Add suffix “-BB” to Product
Number. See DSP-BB for
detailed specification.