Installation Guide
MODELS:
ITG50/VFB050B4A1
INSTALLATION AND OPERATING INSTRUCTIONS
VENTILATION FAN
READ AND SAVE THESE INSTRUCTIONS
General Safety Information
1. Make sure that the electric service supply
voltage is AC 120V, 60Hz.
2. Follow all local electrical and safety codes, as
well as the National Electrical Code (NEC) and
the Occupational Safety and Healthy Act
(OSHAct).
3. Always disconnect the power source before
working on or near the ventilating fan, motor or
junction box.
4. Protect the power cord from sharp edges, oil,
grease, hot surfaces, chemicals or other
objects.
5. Do not kink the power cord.
6. Do not install the unit where ducts are
configured as shown in Fig. A.
7. Provide suction parts with proper ventilation.
8. This unit is UL listed for use over a bathtub or
shower when installed in a GFCI protected
branch circuit.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
1. Use this unit only in the manner intended by the
manufacturer. If you have any questions,
contact the manufacturer.
2. Before servicing or cleaning the unit, switch
power off at service panel and lock the service
disconnecting means to prevent power from
being switched on accidentally. When the
service disconnecting means cannot be locked,
securely fasten a prominent warning device,
such as a tag, to the service panel.
3. Installation work and electrical wiring must be
done by qualified person(s) in accordance with
all applicable codes and standards, including
fire-rated construction.
4. Sufficient air is needed for proper combustion
and exhausting of gases through the flue
(chimney) of fuel burning equipment to prevent
back drafting. Follow the heating equipment
manufacturer’s guideline and safety standards
such as those published by the National Fire
Protection Association (NFPA), and the
American Society for Heating, Refrigeration and
Air Conditioning Engineers (ASHRAE), and the
local code authorities.
5. When cutting or drilling into ceiling, do not
damage electrical wiring and other hidden
utilities.
6. Ducted fans must always be vented to the
outdoors.
7. If this unit is to be installed over a tub or shower,
it must be marked as appropriate for the
application and be connected to a GFCI
(Ground Fault Circuit Interrupter) – protected
branch circuit.
8. Do not use this unit with any other solid-state
control device. Solid-state controls devices may
cause harmonic distortion, which can cause a
motor humming noise.
9. NEVER place a switch where it can be reached
from a tub or shower.
10. Not to be installed in a ceiling thermally
insulated to a value greater than R50. (This is
required for installation in Canada only).
CAUTION
1. For General Ventilating Use Only. Do Not Use
To Exhaust Hazardous Or Explosive Materials
And Vapors.
2. Not for use in cooking area. (Fig. B)
3. This product must properly connect to the
grounding conductor of the supply circuit.
4. To reduce the risk of injury to persons, install
the fan at least 8.2 feet (2.5m) above the floor.
Cooking area
SUPPLIED ACCESSORIES
Part name
Appearance Quantity
Grille
1
Fan
1
Housing
1
4” Duct
1
Screw
(M4x12)
3
DIMENSIONS
SPECIFICATIONS
Note: Design and specifications are subject to
change without notice.
Operation
1. Single Speed Model: ITG80
Single speed control mode: Turn the power
switch to operate ON/OFF.
MAINTENANCE WARNING:
Disconnect the power source before working on the
unit. Routine maintenance must be done every year.
CAUTION:
1. Never use gasoline, benzene, thinner or any
other such chemicals for cleaning the
ventilating fan.
2. Do not allow water to enter the motor.
3. Do not soak resin parts in water over 60°C (140
o
F).
CLEANING
1. Pull down the spring to remove the grille.
2. Wash and clean the grille. (Use non-abrasive
kitchen detergent and wipe dry with a new
cloth.)
3. Remove dust and dirt from the ventilating fan
using a vacuum cleaner.
4. Using a cloth dampened with kitchen detergent,
remove any dirt from the ventilating fan. Wipe
dry with a new cloth.
5. Replace the grille.
Model No.
Voltage
(V)
Frequency
(Hz)
Power
(W)
Air Flow
@ 0.1SP
(CFM)
Weight
(lb.)
Note
ITG50
120
60 8 50
4.0
Single
Speed
VFB050B4A1
120
60 8 50
4.0
Single
Speed
Fig. A
Fig. B