Specifications
M
J
A
PRIMARY AIR ADJUSTMENT OF THE BURNERS
By operating the screw “M”, reset the air adjuster “A” according to the instructions
see “Injector table”, where the distance between injector and air adjuster is
recommended (in mm).
Before refixing the hob top, set the burners on their sites and light them in order
to check whether the flames are correct, as per the specifications given above.
In case of uncorrect flame, lift or lower the air adjuster.
Figure 11
Flame faulty in Flame correct Flame with excess
primary air primary air
long, yellow and trembling clear interior blue cone short and sharp
too blue interior cone
tending to detach
CAUSE
air regulating tube, correct distance air regulating tube,
too closed of the tube too open
14