Users Guide
318 | Using VisualRF Dell Networking W-AirWave 7.7 | User Guide
Setting Default Description
l After the minimum timer (default is 30 seconds), check to see if the
number of data samples received from all APs that hear this client are
greater than or equal to the number of samples setting for legacy laptop
devices (default of 4 data samples).
l If so (Yes to question above), then recalculate the client device's
location based on the samples received.
l If not (No to the question above), then wait until the number of sample
setting is met before recalculating. If the number of samples is never
met, wait until the maximum timer (default is 120 seconds) and then
recalculate.
RFID Number of
Samples
4 See definition above.
Scale Min/Max (sec) 500/2000
Scale Number of
Samples
3
Printer Min/Max
(sec)
120/480
This timer determines how often to calculate the location of printers. Taken
with the data samples the calculation acts as follows:
l After the minimum timer (default is 120 seconds), check to see if the
number of data samples received from all APs that hear this client are
greater than or equal to the number of samples setting for legacy laptop
devices (default of 3 data samples).
l If so (Yes to question above), then recalculate the client device's
location based on the samples received.
l If not (No to the question above), then wait until the number of sample
setting is met before recalculating. If the number of samples is never
met, wait until the maximum timer (default is 480 seconds) and then
recalculate.
Printer Number of
Samples
3 See definition above.
Rogue Min/Max
(sec)
500/2000
This timer determines how often to calculate the location of rogues. Taken
with the data samples the calculation acts as follows:
l After the minimum timer (default is 500 seconds), check to see if the
number of data samples received from all APs that hear this client are
greater than or equal to the number of samples setting for legacy laptop
devices (default of 3 data samples).
l If so (Yes to question above), then recalculate the client device's
location based on the samples received.
l If not (No to the question above), then wait until the number of sample
setting is met before recalculating. If the number of samples is never
met, wait until the maximum timer (default is 2000 seconds) and then
recalculate.
Rogue Number of
Samples
3 See definition above.
Default Min/Max
(sec)
90/360
Default Number of
Samples
3
Attenuation Settings
Attenuation settings describe type and dB settings for walls within a floor plan.