Users Guide

Dell Event ID Alert Description on
Operations Manager
and PRO Tip in VMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action
2246 The controller battery
is degraded
Warning The temperature of the
the battery is high. This
maybe due to the
battery being charged.
Restrict
2264 A device is missing Warning The controller cannot
communicate with a
device. The device
may be removed.
Restrict
2265 A device is in an
unknown state
Warning The controller cannot
communicate with a
device. The state of
the device cannot be
determined.
Restrict and Migrate
2268 Storage Management
communication Error
Critical Storage Management
has lost
communication with a
controller. This may
occur if the controller
driver or firmware is
experiencing a
problem.
Restrict and Migrate
2272 Patrol Read found an
uncorrectable media
error
Critical The Patrol Read task
has encounted an
error that cannot be
corrected. There may
be a bad disk block
that cannot be
remapped.
Restrict and Migrate
2273 A block on the physical
disk has been
punctured by the
controller
Critical The controller
encountered an
unrecoverable medium
error when attempting
to read a block on the
physical disk and
marked that block as
invalid.
Restrict and Migrate
2282 Hot spare SMART
polling failed
Warning The controller
firmware attempted to
do SMART polling on
the hot spare but was
not able to complete
the SMART polling.
Restrict and Migrate
2283 A redundant path is
broken
Warning The controller has two
connectors that are
Restrict and Migrate
19