User's Manual

Dell Event ID Alert Description on
Operations Manager
and PRO Tip in VMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action
2169 The controller battery
needs to be replaced
Critical The controller battery
cannot recharge. The
battery may have been
already recharged the
maximum number of
times. In addition, the
battery charger may
not be working.
Restrict and Migrate
2171 The controller battery
temperature is above
normal
Warning The room temperature
may be too hot. The
system fan may also
be degraded or failed.
Restrict
2174 The controller battey
has been removed
Warning The controller cannot
communicate with the
battery. The battery
may be removed or the
contact point maye
degraded
Restrict and Migrate
2178 The controller battery
Learn cycle has timed
out
Warning The controller battery
must be fully charged
before the Learn cycle
can begin.
Restrict
2187 Single-bit ECC error
limit exceeded on the
controller DIMM
Warning The controller memory
is malfunctioning.
Restrict and Migrate
2201 A global hot spare
failed
Warning The controller is not
able to communicate
with a disk that is
assigned as a global
hot spare. The disk
may have failed or
been removed.
Restrict
2203 A dedicated hot spare
failed
Warning The controller is not
able to communicate
with a disk that is
assigned as a
dedicated hot spare.
Restrict
2206 The only hot spare
available is a SATA
disk. SATA disks
cannot replace SAS
disks
Warning The only physical disk
available to be
assigned as a hot
spare is using SATA
technology.
Restrict
17