User's Manual

Dell Event ID Alert Description on
Operations Manager
and PRO Tip in VMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action
excessive
temperature.
2101 Temperature dropped
below Minimum
Warning Threshold
Warning The physical disk
enclosure is too cool.
Restrict
2102 Temperature
exceeded Maximum
Failure Threshold
Critical The physical disk
enclosure is too hot. A
variety of factors can
cause the excessive
temperature.
Restrict and Migrate
2103 Temperature dropped
below the Minimum
Failure Threshold
Critical The physical disk
enclosure is too cool.
Restrict and Migrate
2112 Enclosure shutdown Critical The physical disk
enclosure is either
hotter or cooler than
the maximum or
minimum allowable
temperature range.
Restrict and Migrate
2122 Redundancy degraded Warning One or more of the
enclosure components
has failed. For
example, a fan or
power supply may
have failed.
Restrict
2123 Redundancy Lost Warning A virtual disk or an
enclosure has lost
data redundancy.
Restrict and Migrate
2125 Controller cache
pinned for missing or
offline VD
Warning Controller getting
disconnected from its
VD, while IO is
happening
Restrict
2129 BGI (Back Ground
Initialization) Failed
Error
Critical BGI of a virtual disk
has failed.
Restrict
2137 Communication Time-
out Warning
Warning The controller is
unable to
communicate with an
enclosure.
Restrict and Migrate
2145 Controller battery low Warning The controller battery
charge is low.
Restrict
16