User's Manual

9. Click Apply
CAUTION: Saving the settings in the default management pack, creates a dependency between PRO Pack and the
management pack. When you remove or delete PRO Pack, you must delete the default management pack as well,
as it contains default settings for Operations Manager. Hence, it is recommended that you save settings using a
new MP.
10. Click OK .
11. Generate an alert and PRO Tip.
12. Select Implement PRO Tip.
This verifies that the overridden recovery action is successful.
Figure 2. Override Properties
Alerts and Recovery Actions
The following table lists the alerts and the recommended remedial actions:
Dell Event ID Alert Description on
Operations Manager
and PRO Tip in VMM
Severity Alert Cause Dell PRO Tip
Recommended
Remedial Action
1053 Temperature sensor
detected a warning
value
Warning A temperature sensor
on the backplane
board, system board,
CPU, or drive carrier in
the specified system
exceeded its warning
threshold value.
Restrict
1054 Temperature sensor
detected a failure
value
Error A temperature sensor
on the backplane
board, system board,
CPU, or drive carrier in
the specified system
exceeded its failure
threshold value.
Restrict and Migrate
1104 Fan sensor detected a
failure value
Error A fan sensor in the
specified system
Restrict
13