Setup Guide

Upgrading to OpsMgr 2012
NOTE: Close or resolve all the Chassis and DRAC alerts before upgrading to OpsMgr 2012. It is recommended to
take a backup of Chassis monitoring and DRAC monitoring override references for Custom Group and Instance
Level override as those overrides may be lost during the upgrade.
If you have already imported the Dell Server Management Pack Suite version 5.0.1 MPs on your system and then
upgraded to OpsMgr 2012, the Chassis and DRAC monitoring feature will be automatically upgraded in the next Feature
Monitoring Pack discovery cycle. During this upgrade, Chassis Monitoring and DRAC Monitoring Management Packs
specific to OpsMgr 2007 will remain along with the just imported OpsMgr 2012 specific Chassis Monitoring and DRAC
Monitoring Management Packs.
In OpsMgr 2012, the Network Monitoring Stack has been upgraded, to use the new Network Monitoring features in
OpsMgr 2012, it is recommended to re-discover the Dell devices using the new OpsMgr 2012 Network Device Discovery
Wizard. After the Chassis Monitoring and DRAC Monitoring features have been upgraded in OpsMgr 2012, it is
recommended to:
Remove the Chassis and DRAC devices that are under Legacy Network Devices.
Rediscover the Chassis and DRAC devices as nodes. For more information, see technet.microsoft.com/en-us/library/
hh278846.aspx.
Remove the Dell CMC (SCOM 2007/SCE 2010) MP and Dell DRAC (SCOM 2007/SCE 2010) MP files from OpsMgr 2012
as the functions of these MPs are performed by Dell CMC (SC2012 OM) MPs and Dell DRAC (SC2012 OM) MPs in
OpsMgr 2012.
For details on how to upgrade from OpsMgr 2007 to OpsMgr 2012, see technet.microsoft.com/en-us/library/
hh476934.aspx.
NOTE: To make sure that the feature management workflows are functioning at an optimal level, restart the root
management server after upgrading to OpsMgr 2012.
Post-Installation or Upgrade Tasks For The Dell Server
Management Pack Suite
Perform the following post-installation tasks after you import the management packs:
1. Configure CMC Monitoring feature for discovering Chassis Slots Summary and Server Modules.
For more information, see Configuring Dell Chassis Management Controller Feature For Correlating Server Modules
With Chassis Slot Summary .
2. Configure Dell Server Management Pack Suite to get licenses from Dell Connections License Manager to enable
Server (Out-of-band) Monitoring feature.
For more information, see Configuring Dell Connections License Manager URL.
Configuring OpsMgr 2012 To Enable Monitoring Traps And Trap Based Unit Monitors
To enable monitoring, traps, and trap-based unit monitors in OpsMgr 2012:
1. Launch OpsMgr 2012, and click Administration.
2. In the Administration pane, browse to Run As Configuration Profiles.
3. From the list of available profiles, right-click SNMP Monitoring Account and click Properties.
The Introduction screen is displayed.
4. Click Next.
The General Properties screen is displayed.
22