Owners Manual
About Your System 33
E201A SuperIO
failure. Power
cycle AC.
SIO failure. Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 177.
E201B Keyboard
Controller
error. Power
cycle AC.
Keyboard controller
failure.
Remove AC power to the
system for 10 seconds and
restart the system.If the
problem persists,
see "Getting Help" on
page 177.
E201C SMI
initialization
failure. Power
cycle AC.
System management
interrupt (SMI)
initialization failure.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 177.
E201D Shutdown test
failure. Power
cycle AC.
BIOS shutdown test
failure.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 177.
E201E POST memory
test failure.
Check DIMMs.
BIOS POST memory test
failure.
See "Troubleshooting
System Memory" on
page 154.
If the problem persists,
see "Getting Help" on
page 177.
E2020 CPU
configuration
failure. Check
screen
message.
Processor configuration
failure.
Check screen for specific
error messages.
See "Troubleshooting the
Microprocessors" on
page 162.
Table 1-2. LCD Status Messages (Optional) (continued)
Code Text Causes Corrective Actions
book.book Page 33 Thursday, August 13, 2009 7:27 AM