Reference Guide

Dell PowerVault ML6000 Basic SNMP Reference Guide 131
--#TYPE "Startup Sequence Completed"
--#SUMMARY "The library %s has completed its bootup
sequence and is at status %d."
--#ARGUMENTS {0,1}
--#SEVERITY INFORMATIONAL
::= { tapeLibraryMIBNotifications 101 }
shutdownSequenceInitiated NOTIFICATION-TYPE
OBJECTS {
librarySerialNumber,
libraryGlobalStatus
}
STATUS current
DESCRIPTION "Notify that the library has started its
reboot sequence."
--#TYPE "Shutdown Sequence Initiated"
--#SUMMARY "The library %s has initiated shutdown
sequence and is at status %d."
--#ARGUMENTS {0,1}
--#SEVERITY INFORMATIONAL
::= { tapeLibraryMIBNotifications 102 }
phLibrayStateChange NOTIFICATION-TYPE
OBJECTS {
librarySerialNumber,
physicalLibraryState
}
STATUS current
DESCRIPTION "Notify that the online state of the physical library
changed."
--#TYPE "Change in Online state of the Physical Library"
--#SUMMARY "The library %s has changed its online
state and is at state %d."
--#ARGUMENTS {0,1}
--#SEVERITY INFORMATIONAL
::= { tapeLibraryMIBNotifications 103 }
moduleDoorStatusChange NOTIFICATION-TYPE