Users Guide
support.dell.com PowerVault 51F Commands 4-9
Figure 4-3. configure Command Behavior With Out-of-Range or
Inappropriate Inputs
A number of parameters control the overall behavior and operation of the fabric. Some
of these values, such as the domain, are normally assigned automatically by the fabric
and may be different from one switch to another in the fabric. However, other param-
eters, such as the buffer-to-buffer credit or the time out values, may be changed to
suit particular application programs or operating environments, but must be in agree-
ment among all switches to allow formation of the fabric.
Table 4-4 defines the settings affecting the fabric.
Table 4-4. Fabric Settings
Field Type Default Range
Domain Number 1 Varies
BB Credit Number 16 1 - 16
R_A_TOV Number 10000 E_D_TOV
*
2 to
120000
E_D_TOV Number 2000 1000 to R_A_TOV / 2
Data Field Size Number 2112 256 to 2112
Non-SCSI Tachyon Mode Boolean 0 0 or 1
Disable Device Probing Boolean 0 0 or 1
VC Encoded Address
Mode
Boolean 1 0 or 1
Disable Translative Mode Boolean 0 0 or 1
Per-frame Route Priority Boolean 0 0 or 1
switch:admin> configure
Configure...
Fabric parameters (yes, y, no, n): [no] y
Domain: (1..239) [0] 256
integer must be between 1 and 239 - please re-enter
Domain: (1..239) [0]
BB credit: (1..16) [16] one
Input not acceptable, please re-enter
BB credit: (1..16) [16]
R_A_TOV: (4000..120000) [10000]
E_D_TOV: (1000..5000) [2000] 4900
integer must be a multiple of 1000 - please re-enter
E_D_TOV: (1000..5000) [2000] 5000
Data field size: (256..2112) [2112] ^D
Committing configuration...done.