Connectivity Guide

Table Of Contents
Command Mode CONFIGURATION
Usage Information
You can enable only one of the following at a time: F_Port, NPG, or FSB. The no version of this command disables
NPG mode.
Example
OS10(config)# feature fc npg
Supported Releases 10.4.0E(R1) or later
show npg devices
Displays the NPG devices connected to the switch.
Syntax
show npg devices [brief]
Parameters None
Default Not congured
Command Mode EXEC
Usage Information Use the brief option to display minimum details.
Example
OS10# show npg devices
Enode[0]:
Enode MAC :d4:ae:52:1a:ee:54
Enode Interface: port-channel10(Eth 1/1/9)
FCF MAC :14:18:77:20:7c:e3
Fabric Interface :Fc 1/1/25
FCoE Vlan :1001
Vfabric Id :10
ENode WWPN :20:01:d4:ae:52:1a:ee:54
ENode WWNN :20:00:d4:ae:52:1a:ee:54
FCoE MAC :0e:fc:00:01:04:02
FC-ID :01:04:02
Login Method :FLOGI
Time since discovered(in Secs) :6253
Status :LOGGED_IN
Example (brief)
Total NPG Devices = 1
ENode-Interface ENode-WWPN FCoE-Vlan Fabric-Intf Vfabric-Id LoginMethod Status
-------------------------------------------------------------------------------------------------
Po 10(Eth 1/1/9) 20:01:d4:ae:52:1a:ee:54 1001 Fc 1/1/25 10 FLOGI
LOGGED_IN
Supported Releases 10.4.0E(R1) or later
F_Port and NPG commands
The following commands are supported on both F_Port and NPG modes:
clear fc statistics
Clears FC statistics for specied vfabric or bre channel interface.
Syntax
clear fc statistics [vfabric vfabric-ID | interface fibrechannel]
Fibre Channel 149