Administrator Guide
520962048 213778432 dosFs2.0 USERFLASH rw flash:
127772672 21936128 dosFs2.0 USERFLASH rw slot0:
- - - network rw ftp:
- - - network rw tftp:
- - - network rw scp:
You can change the default le system so that le management commands apply to a particular device or memory.
To change the default directory, use the following command.
• Change the default directory.
EXEC Privilege mode
cd directory
View Command History
The command-history trace feature captures all commands entered by all users of the system with a time stamp and writes these
messages to a dedicated trace log buer.
The system generates a trace message for each executed command. No password information is saved to the le.
To view the command-history trace, use the show command-history command.
Example of the show command-history Command
Dell#show command-history
[12/5 10:57:8]: CMD-(CLI):service password-encryption
[12/5 10:57:12]: CMD-(CLI):hostname Force10
[12/5 10:57:12]: CMD-(CLI):ip telnet server enable
[12/5 10:57:12]: CMD-(CLI):line console 0
[12/5 10:57:12]: CMD-(CLI):line vty 0 9
[12/5 10:57:13]: CMD-(CLI):boot system rpm0 primary flash://FTOS-CB-1.1.1.2E2.bin
Upgrading Dell Networking OS
NOTE
: To upgrade Dell Networking Operating System (OS), refer to the Release Notes for the version you want to load on the
system.
Using HTTP for File Transfers
Stating with Release 9.3(0.1), you can use HTTP to copy les or conguration details to a remote server. To transfer les to an external
server, use the copy source-le-url http://host[:port]/le-path command.
Enter the following source-le-url keywords and information:
• To copy a le from the internal FLASH, enter ash:// followed by the lename.
• To copy the running conguration, enter the keyword running-cong.
• To copy the startup conguration, enter the keyword startup-cong.
• To copy a le on the USB device, enter usbash:// followed by the lename.
In the Dell Networking OS release 9.8(0.0), HTTP services support the VRF-aware functionality. If you want the HTTP server to use a VRF
table that is attached to an interface, congure that HTTP server to use a specic routing table. You can use the ip http vrf command
to inform the HTTP server to use a specic routing table. After you congure this setting, the VRF table is used to look up the destination
address.
NOTE
: To enable HTTP to be VRF-aware, as a prerequisite you must rst dene the
VRF.
You can specify either the management VRF or a nondefault VRF to
congure the VRF awareness setting.
54
Getting Started