Test 12.002 - FanTray2 AirFlow Type Test ............................ PASS
Test 12 - FanTray AirFlow Type Test ................................. PASS
Test 13.000 - I2c Access Test ....................................... PASS
Test 13.001 - I2c Access Test ....................................... PASS
Test 13.002 - I2c Access Test ....................................... PASS
Test 13.003 - I2c Access Test ....................................... PASS
Test 13.004 - I2c Access Test ....................................... PASS
Test 13.005 - I2c Access Test ....................................... PASS
Test 13.006 - I2c Access Test ....................................... PASS
Test 13.007 - I2c Access Test ....................................... PASS
Test 13.008 - I2c Access Test ....................................... PASS
Test 13.009 - I2c Access Test ....................................... PASS
Test 13.010 - I2c Access Test ....................................... PASS
Test 13.011 - I2c Access Test ....................................... PASS
Test 13.012 - I2c Access Test ....................................... PASS
Test 13.013 - I2c Access Test ....................................... PASS
You can run Offline diagnostics in debug mode as shown in the following example, Running Offline
Diagnostics in DEBUG Mode. Dell highly recommends reloading the system after running the offline
diagnostics in debug mode.
Figure 13-5. Running Offline Diagnostics in DEBUG Mode
FTOS#diag stack-unit 0 level0 verbose no-reboot
Warning - diagnostic execution will cause multiple link flaps on the peer side - advisable to shut
directly connected ports
Warning - It is highly recommended to reboot the system after Offline Diagnostics
Proceed with Diags [confirm yes/no]: yes
FTOS#May 9 13:04:34: %S6000:0 %DIAGAGT-6-DA_DIAG_STARTED: Starting diags on stack unit 0
01:30:33 : Approximate time to complete the Diags ... 2.5 Mins
FTOS#diag stack-unit 0 alllevels verbose no-reboot
Warning - diagnostic execution will cause multiple link flaps on the peer side - advisable to shut
directly connected ports
Warning - It is highly recommended to reboot the system after Offline Diagnostics
Proceed with Diags [confirm yes/no]: yes
FTOS#May 9 13:11:31: %S6000:0 %DIAGAGT-6-DA_DIAG_STARTED: Starting diags on stack unit 0
01:37:30 : Approximate time to complete the Diags ... 14 Mins
WARNING: Reboot is highly recommended after running Offline Diagnostics in Debug Mode. Debug Mode can be
used only for troubleshooting specific test issue.
5. View offline diagnostics with the show diag information command (show diag information
Command Example) or the
show diag stack-unit command (show diag stack-unit Command
Example).