The S5296F-ON PSUs:
1. PSUs
The S5212F-ON AC PSUs:
1. AC PSUs
The S5212F-ON DC PSUs:
1. DC PSUs
The PSUs have an integrated fan, which you cannot replace individually; if the fan integrated in a PSU fails, you must replace
the entire PSU. You can replace the fan trays individually. For fan tray replacement procedures, see Fans.
WARNING:
Prevent exposure and contact with hazardous voltages. Do not attempt to operate this switch with
the safety cover removed.
CAUTION: Remove the power cable from the PSU before removing the PSU. Also, do not connect the power
cable before you insert the PSU in the switch.
NOTE: To comply with the GR-1089 Lightning Criteria for Equipment Interfacing with AC or DC Power Ports, use an
external surge protection device (SPD) at the AC or DC input of the router.
PSU LEDs
● Solid green—Input is OK.
● Flashing yellow—There is a fault with the PSU.
● Flashing green blink at 1Hz—Switch is in a standby/CR state.
● Off—PSU is off.