Reference Guide

Getting Started | 51
Figure 3-4. Completed Boot Process (3 of 3 screens)
Entering the Initial Configuration Information
To set up the switch, you need to assign an IP address and other configuration information necessary for
the switch to communicate with the local routers and the Internet. The minimal configuration provided
here does not cover most of the features; it simply allows you to perform other configuration tasks using a
Telnet connection from your management network.
You will need this information from your network administrator:
Switch IP address
Subnet mask (IP netmask)
Default gateway (router)
Enable secret password
Enable password
Telnet password
00:00:38: %STKUNIT0-M:CP %RAM-6-ELECTION_ROLE: Stack unit 0 is transitioning to Management unit.
00:00:39: %STKUNIT0-M:CP %CHMGR-5-STACKUNITDETECTED: Stack unit 0 present
00:00:44: %S5000:0 %POLLMGR-2-USER_FLASH_STATE: USB flash disk missing in 'usbflash:'
00:03:01: %STKUNIT0-M:CP %CHMGR-5-MODULE_INSERTED: FC module has been inserted in stack-unit 0
optional slot 0
00:03:01: %STKUNIT0-M:CP %CHMGR-5-MODULE_INSERTED: SFP+ module has been inserted in stack-unit 0
optional slot 1
00:03:01: %STKUNIT0-M:CP %CHMGR-5-MODULE_INSERTED: SFP+ module has been inserted in stack-unit 0
optional slot 2
00:03:01: %STKUNIT0-M:CP %CHMGR-5-MODULE_INSERTED: SFP+ module has been inserted in stack-unit 0
optional slot 3
00:03:01: %STKUNIT0-M:CP %CHMGR-5-CHECKIN: Checkin from Stack unit 0 (type S5000, 64 ports)
00:03:02: %STKUNIT0-M:CP %CHMGR-2-FANTRAY_UP: Fan Tray 1 in unit 0 is up
00:03:02: %STKUNIT0-M:CP %CHMGR-2-FANTRAY_UP: Fan Tray 2 in unit 0 is up
00:03:03: %STKUNIT0-M:CP %CHMGR-0-PS_UP: Power supply 0 in unit 0 is up
00:03:04: %STKUNIT0-M:CP %CHMGR-0-PS_UP: Power supply 1 in unit 0 is up
00:03:04: %STKUNIT0-M:CP %CHMGR-5-STACKUNITUP: Stack unit 0 is up
00:03:05: %STKUNIT0-M:CP %CHMGR-5-SYSTEM_READY: System ready
00:03:05: %STKUNIT0-M:CP %RAM-5-STACK_STATE: Stack unit 0 is in Active State.
00:03:05: %STKUNIT0-M:CP %IFMGR-5-OSTATE_UP: Changed interface state to up: Ma 0/0
00:03:17: %STKUNIT0-M:CP %CHMGR-1-PSU_FAN_STATUS: Fan 0 in PSU 0 of Unit 0 is up
00:03:17: %STKUNIT0-M:CP %CHMGR-1-PSU_FAN_STATUS: Fan 0 in PSU 1 of Unit 0 is up
Dell>00:03:24: %STKUNIT0-M:CP %SEC-5-LOGIN_SUCCESS: Login successful for user on line console
Dell>
Dell>
Dell>enable
Dell#
<prompt available and admin enable logged in >
========== end of boot up process ===========