Reference Guide

SNMP Traps | 1575
%TSM-5-SFM_REMOVE: Removed SFM 1
CHM_MAJ_SFM_DOWN ENVMON NONE
%CHMGR-0-MAJOR_SFM: Major alarm: Switch fabric down
CHM_MAJ_SFM_DOWN_CLR ENVMON NONE
%CHMGR-5-MAJOR_SFM_CLR: Major alarm cleared: Switch fabric up
CHM_MIN_SFM_DOWN ENVMON NONE
%CHMGR-2-MINOR_SFM: MInor alarm: No working standby SFM
CHM_MIN_SFM_DOWN_CLR ENVMON NONE
%CHMGR-5-MINOR_SFM_CLR: Minor alarm cleared: Working standby SFM present
CHM_PWRSRC_DOWN ENVMON SUPPLY
%CHMGR-2-PEM_PRBLM: Major alarm: problem with power entry module %s
CHM_PWRSRC_CLR ENVMON SUPPLY
%CHMGR-5-PEM_OK: Major alarm cleared: power entry module %s is good
CHM_MAJ_ALARM_PS ENVMON SUPPLY
%CHMGR-0-MAJOR_PS: Major alarm: insufficient power %s
CHM_MAJ_ALARM_PS_CLR ENVMON SUPPLY
%CHMGR-5-MAJOR_PS_CLR: major alarm cleared: sufficient power
CHM_MIN_ALARM_PS ENVMON SUPPLY
%CHMGR-1-MINOR_PS: Minor alarm: power supply non-redundant
CHM_MIN_ALARM_PS_CLR ENVMON SUPPLY
%CHMGR-5-MINOR_PS_CLR: Minor alarm cleared: power supply redundant
CHM_MIN_ALRM_TEMP ENVMON TEMP
%CHMGR-2-MINOR_TEMP: Minor alarm: chassis temperature
CHM_MIN_ALRM_TEMP_CLR ENVMON TEMP
%CHMRG-5-MINOR_TEMP_CLR: Minor alarm cleared: chassis temperature normal (%s %d temperature is within
threshold of %dC)
CHM_MAJ_ALRM_TEMP ENVMON TEMP
%CHMGR-2-MAJOR_TEMP: Major alarm: chassis temperature high (%s temperature reaches or exceeds threshold of
%dC)
CHM_MAJ_ALRM_TEMP_CLR ENVMON TEMP
%CHMGR-2-MAJOR_TEMP_CLR: Major alarm cleared: chassis temperature lower (%s %d temperature is within
threshold of %dC)
CHM_FANTRAY_BAD ENVMON FAN
For E1200: %CHMGR-2-FAN_TRAY_BAD: Major alarm: fan tray %d is missing or down
%CHMGR-2-ALL_FAN_BAD: Major alarm: all fans in fan tray %d are down.
For E600 and E300: %CHMGR-2-FANTRAYBAD: Major alarm: fan tray is missing
%CHMGR-2-FANSBAD: Major alarm: most or all fans in fan tray are down
Table 60-1. SNMP Traps and Error Messages (continued)
Message ID Trap Type Trap Option