• ADDRESS_WRITE—Write test of the address lines.
• ADDRESS_WALKING1—Walking a 1 through the address lines within the memory space.
• ADDRESS_WALKING0—Walking a 0 through the address lines within the memory space.
• DATA_READ—Read test of the data lines.
• DATA_WRITE—Write test of the data lines.
• DATA_WALKING1—Walking a 1 through the data lines.
• DATA_WALKING0—Walking a 0 through the data lines.
• DATA_SLIDING1—Sliding a 1 through the data lines.
• DATA_SLIDING0—Sliding a 0 through the data lines.
• DATA_PATTERN—Writing and reading patterns from the memory.
• DATA_CACHE—Exercises the RAM by completing cache evictions by rotating a large array, usually cache-line size square, of the values
in memory multiple times.
• SPD Device—Not used.
• SPD Access—Bus to use to access the SPD.
• SPD Address—The address of the SPD chip (in hex) on the bus, if applicable.
• SPD Registers—The valid registers of the SPD chip listed as start,end.
DDR3-0
Start Address:-
Size:-
Access Mode:d
Increment:8
Ecc:1
Max Chunk:2800
Max Cache:0
Cache Line:0
Iterations:1
Tests:ALL_TESTS
SPD Device:SPD
SPD Access:/dev/i2c-0
SPD Address:50
SPD Registers:0,ff
nputool
The nputool allows for conguring and testing the switch ASICs.
The nputool tests the NPU in the system. The nputool veries that ports are up and trac between the ports is working either using
the CPU-generated packet or using IXIA connected to port-1 and port-2 based on the conguration.
Tests
Tests are shown in the following sections.
CLI options
The nputool shows the available options with the nputool -h or nputool command.
DellEmc Diag ---- NPU Tool
version 1.0, x.xx.x.x-x
build, 2017/05/23,
Syntax: nputool
-h, --help := Show this help
-i, --init := Initialize NPU chip
50