Users Guide

Table Of Contents
FC MTU 2188 bytes
LineSpeed 0
Operational Speed 0 over 20G
Port type is E_Port, Max BB credit is 8
WWN is 20:01:14:18:77:20:73:cf
Last clearing of "show interface" counters: 1 day 16:33:56
Input statistics:
0 frames, 0 bytes
0 class 2 good frames, 0 class 3 good frames
0 frame too long, 0 frame truncated, 0 CRC
0 link fail, 0 sync loss
0 primitive seq err, 0 LIP count
0 BB credit 0, 0 BB credit 0 packet drops
Output statistics:
0 frames, 0 bytes
0 class 2 frames, 0 class 3 frames
0 BB credit 0, 0 oversize frames
0 total errors
Rate Info:
Input 0 bytes/sec, 0 frames/sec, 0% of line rate
Output 0 bytes/sec, 0 frames/sec, 0% of line rate
Time since last interface status change: 1 day 16:33:57
Supported
Releases
10.5.1.0 or later
show vfabric
Shows the fc timer, E_D_TOV, R_A_TOV, principal switch priority, and domain ID values in the show vfabric command.
Syntax
show vfabric value
Parameters
valueValid values are from 1 to 255.
Defaults Not applicable
Command Mode GLOBAL CONFIGURATION
Usage
Information
Use this command to display the fc timers, E_D_TOVand R_A_TOV, principal switch priority and domain
ID values. Also, this command shows the configured domain ID, run-time domain ID, and the principal
switch priority of the switch.
Example
OS10# show vfabric
Fabric Name SAN_FABRIC
Fabric Type Multi-Switch
Fabric Id 10
VlanId 1002
FC-MAP 0xEFC00
FCF Priority 128
FKA-Adv-Period Enabled, 8
Config-State ACTIVE
Oper-State UP
=================================================
Switch Config Parameters
==================================================
Domain ID 3
Switch Priority 3
E-D-TOV(ms) 1000
R-A-TOV(ms) 5000
==================================================
Switch Fabric Parameters
==================================================
Run Time Domain ID 4
Run Time Switch Priority 3
==================================================
Switch Zoning Parameters
=================================================
Default Zone Mode: Deny
Fibre Channel 371