View running conguration of monitor session
OS10# show running-configuration monitor
!
monitor session 10 type erpm-source
source-ip 1.1.1.1 destination-ip 3.3.3.3
source interface ethernet1/1/2
no shut
Flow-based monitoring
Flow-based monitoring conserves bandwidth by inspecting only specied trac instead of all interface trac. Using ow-based monitoring,
you can monitor only trac received by the source port that matches criteria in ingress access-lists (ACLs). IPv4 ACLs, IPv6 ACLs, and
MAC ACLs support ow-based monitoring.
1 Enable ow-based monitoring for a monitoring session in MONITOR-SESSION mode.
flow-based enable
2 Return to CONFIGURATION mode.
exit
3 Create an access list in CONFIGURATION mode.
ip access-list access-list-name
4 Dene access-list rules using seq, permit, and deny statements in CONFIG-ACL mode. ACL rules describe the trac to monitor.
seq sequence-number {deny | permit} {source [mask] | any | host ip-address} [count [byte]]
[fragments] [threshold-in-msgs count] [capture session session-id]
5 Return to CONFIGURATION mode.
exit
6 Apply the ow-based monitoring ACL to the monitored source port in CONFIGURATION mode. The access list name can have a
maximum of 140 characters.
ip access-group access-list-name {in | out}
Enable ow-based monitoring
OS10(config)# monitor session 1
OS10(conf-mon-local-1)# flow-based enable
OS10(conf-mon-local-1)# exit
OS10(config)# ip access-list ipacl1
OS10(conf-ipv4-acl)# deny ip host 1.1.1.23 any capture session 1 count
OS10(conf-ipv4-acl)# exit
OS10(config)# mac access-list mac1
OS10(conf-mac-acl)# deny any any capture session 1
OS10(conf-mac-acl)# exit
OS10(config)# interface ethernet 1/1/9
OS10(conf-if-eth1/1/9)# mac access-group mac1 in
OS10(conf-if-eth1/1/9)# end
OS10# show mac access-lists in
Ingress MAC access-list mac1
Active on interfaces :
ethernet1/1/9
seq 10 deny any any capture session 1 count (0 packets)
Remote port monitoring on VLT
In a network, devices you congure with peer VLT nodes are considered as a single device. You can apply remote port monitoring (RPM) on
the VLT devices in a network.
In a failover case, the monitored trac reaches the packet analyzer connected to the top-of-rack (ToR) through the VLT interconnect link.