Users Guide

Table Of Contents
Description: psu 2 is not working correctly
Raise-time: Mon Jul 29 06:12:30 2019
Ack-time: Mon Jul 29 06:16:35 2019
New: true
Acknowledged: true
-------------------------------------------
Supported Releases 10.2.0E or later
show alarms sequence
Displays information corresponding to the active alarm based on the sequence number that you specify.
Syntax
show alarms sequence sequence-number
Parameters
sequence-number — Enter the sequence number corresponding to the active alarm.
Default None
Command Mode EXEC
Usage Information Use the show alarms command to view all active alarms. Use an active alarm sequence number to view detailed
information about that alarm.
Example
NOS# show alarms sequence 3
Active-alarm details - 1
------------------------------------------
Sequence Number: 3
Severity: major
Type: 1081375
Source: /psu/2
Name: EQM_MORE_PSU_FAULT
Description: psu 2 is not working correctly
Raise-time: Sun 10-07-2018 18:39:47
Ack-time:
State: raised
-------------------------------------------
Supported Releases 10.4.3E or later
show alarms severity
Displays all active alarms corresponding to a specic severity level.
Syntax
show alarms severity severity
Parameters severity — Set the alarm severity:
critical — Critical alarm severity.
major — Major alarm severity.
minor — Minor alarm severity.
warning — Warning alarm severity.
Default Not congured
Command Mode EXEC
Usage Information None