Service Manual

Line Description
RX Power Low
Alarm threshold
Factory-dened setting. Value can dier between SFP and SFP+.
Temp High Warning
threshold
Factory-dened setting. Value can dier between SFP and SFP+.
Voltage High
Warning threshold
Factory-dened setting. Value can dier between SFP and SFP+.
Bias High Warning
threshold
Factory-dened setting. Value can dier between SFP and SFP+.
TX Power High
Warning threshold
Factory-dened setting. Value can dier between SFP and SFP+.
RX Power High
Warning threshold
Factory-dened setting. Value can dier between SFP and SFP+.
Temp Low Warning
threshold
Factory-dened setting. Value can dier between SFP and SFP+.
Voltage Low
Warning threshold
Factory-dened setting. Value can dier between SFP and SFP+.
Bias Low Warning
threshold
Factory-dened setting. Value can dier between SFP and SFP+.
TX Power Low
Warning threshold
Factory-dened setting. Value can dier between SFP and SFP+.
Power Low Warning
threshold
Factory-dened setting. Value can dier between SFP and SFP+.
Temperature Current temperature of the SFPs. If this temperature crosses Temp High alarm/
warning thresholds, the temperature high alarm/warning ag is set to true.
Voltage Current voltage of the SFPs. If this voltage crosses voltage high alarm/warning
thresholds, the voltage high alarm/warning ag is set to true.
Tx Bias Current Present transmission (Tx) bias current of the SFP. If this crosses bias high alarm/
warning thresholds, the TX bias high alarm/warning ag is set to true. If it falls
below the low alarm/warning thresholds, the TX bias low alarm/warning ag is set
to true.
Tx Power Present Tx power of the SFP. If this crosses Tx power alarm/warning thresholds,
the Tx power high alarm/warning ag is set to true. If it falls below the low alarm/
warning thresholds, the Tx power low alarm/ warning ag is set to true.
Rx Power Present receiving (Rx) power of the SFP. This value is either average Rx power or
OMA. This depends on the Rx Power measurement type displayed above. If this
crosses Rx power alarm/warning thresholds, the Rx power high alarm/warning ag
is set to true. If it falls below the low alarm/warning thresholds, the Rx power low
alarm/warning ag is set to true.
Data Ready state
Bar
This eld indicates that the transceiver has achieved power up and data is ready.
This is set to true if data is ready to be sent and set to false if data is being
transmitted.
Rx LOS state This is the digital state of the Rx_LOS output pin. This is set to true if the operating
status is down.
Tx Fault state This is the digital state of the Tx Fault output pin.
644