Administrator Guide
Switch Management Commands 2030
console(config)#power inline management static
console(config)#interface gi1/0/2
console(config-if-Gi1/0/2)#power inline four-pair forced
console(config-if-Gi1/0/2)#power inline limit user-defined 50000
This example displays an interface configured in four-pair power mode.
console#show power inline gigabitethernet 1/0/1 detailed
Port Powered Device State Priority Status Class Power[mW]
--------- ------------------------ ----- -------- ---------- ------- -------
--
Gi1/0/1 auto Low Searching Unknown
Limit Power High Power
Port Type Limit Mode
--------- -------- -------- -----------
Gi1/0/1 None 57000 Enabled
Overload Counter............................... 0
Short Counter ................................. 0
Denied Counter................................. 0
Absent Counter................................. 0
Invalid Signature Counter...................... 0
Output Volts................................... 53
Output Current................................. 0
Temperature.................................... 49
Command History
Description revised in 6.3.5 release.
power inline management
Use the power inline management command in Global Configuration mode
to set the power management type. This command is used along with the
power inline priority
command. Use the no form of this command to set the
management mode to the default.
Syntax
power inline management [unit unit-id]{dynamic | static | class}
no power inline management [unit unit-id]
• dynamic—Dynamic power management