28 Dell EMC PowerStore Events and Alerts Reference Guide
Event Code Severity Alert Call Home Message Repair flow System impact Knowledge Base Article
0x00307106 MINOR TRUE TRUE
Drive in bus %(bus_num)
enclosure %(encl_num)
slot %(enclosure_slot) is
not initialized.
Addition of the drive has
failed. Contact your service
provider.
Drive is not in service. -
0x00307107 MINOR FALSE FALSE
Drive state for bus
%(bus_num) enclosure
%(encl_num) slot
%(enclosure_slot) needs to
be reported.
-
0x00307108 MINOR TRUE FALSE
Drive lifecycle state has
changed.
-
0x00307201 INFO FALSE FALSE
Drive in bus %(bus_num)
enclosure %(encl_num)
slot %(enclosure_slot) has
%(fw_version_error). The
Current firmware version is
%(fw_version).
-
0x00307202 INFO FALSE FALSE
Firmware is in process of
being upgraded for drive in
bus %(bus_num) enclosure
%(encl_num) slot
%(enclosure_slot).
-
0x00307203 MAJOR TRUE FALSE
Firmware version of the
drive in bus %(bus_num)
enclosure %(encl_num)
slot %(enclosure_slot) is
incompatible.
This indicates a failed
firmware upgrade on the
drive. Verify upgrade logs
and contact your service
provider.
Drive will continue to
operate normally.
https://dell.com/support/kbd
oc/000125397
0x00307204 MINOR TRUE TRUE
Firmware version of the
drive in bus %(bus_num)
enclosure %(encl_num)
slot %(enclosure_slot) is
out-of-date.
This indicates a failed
firmware upgrade on the
drive. Verify upgrade logs
and contact your service
provider.
Drive will continue to
operate normally.
-
0x00307301 INFO FALSE FALSE Drive action has changed.
-
0x00307302 MAJOR TRUE TRUE
Drive in bus %(bus_num)
enclosure %(encl_num)
slot %(enclosure_slot) has
failed.
Verify that there are no
related alerts. You may
need to replace the drive.
Drive is not in service.
https://dell.com/support/artic
le/SLN317218
0x00307303 MAJOR TRUE TRUE Drive action has changed.
Please send the resulting
files to Dell EMC.
https://dell.com/support/artic
le/SLN317218
0x00307304 MAJOR TRUE TRUE Drive action has changed.
Contact Dell EMC to
replace the drive.
https://dell.com/support/artic
le/SLN317218
0x00307401 INFO FALSE FALSE Port state has changed.
-
0x00307402 INFO FALSE FALSE
Port link is down but not in
use.
-
0x00307403 INFO FALSE FALSE Port link status is unknown.
-