Event code Severity Alert Call Home Message Repair Flow System Impact Knowledge Base Article
0x01802E03 MAJOR TRUE FALSE
MTU size issues detected while
performing path MTU discovery
of the following storage
network
addresses: %(ping_scheme).
Check port MTU configuration
within cluster nodes and ensure
that it corresponds to the
storage network MTU which
is %(required_mtu).
-
https://www.dell.com/support/
article/SLN320925
0x01802F01 INFO FALSE FALSE
All intra-cluster management
network addresses are
reachable via ICMP from node
network interfaces.
- - -
0x01802F02 MAJOR TRUE FALSE
The following intra-cluster
management network
addresses are not reachable via
ICMP from node network
interfaces: %(ping_scheme).
Check cabling and VLAN
configuration within cluster
nodes and Ethernet switches.
-
https://www.dell.com/support/
article/SLN320935
0x01803001 INFO FALSE FALSE
No MTU size issues were found
while performing path MTU
discovery of the intra-cluster
management network
addresses from the node
network interfaces.
- - -
0x01803002 MINOR FALSE FALSE
Unable to detect MTU size
issues because some of the
intra-cluster management
network IP addresses are not
reachable via ICMP.
- - -
0x01803003 MAJOR TRUE FALSE
MTU size issues detected while
performing path MTU discovery
of the following intra-cluster
management network
addresses: %(ping_scheme).
Check port MTU configuration
within cluster nodes and ensure
that it corresponds to the intra-
cluster management network
MTU which is %(required_mtu).
-
https://www.dell.com/support/
article/SLN320925
0x01803101 INFO FALSE FALSE
All intra-cluster data network
addresses are reachable via
ICMP from node network
interfaces.
- - -
0x01803102 MAJOR TRUE FALSE
The following intra-cluster data
network addresses are not
reachable via ICMP from node
network
interfaces: %(ping_scheme).
Check the cabling and VLAN
configuration within the cluster
nodes and Ethernet switches.
Migration of resources across
the cluster may be impacted.
https://www.dell.com/support/
article/SLN320935
0x01803103 CRITICAL TRUE FALSE
The following intra-cluster data
network addresses are not
reachable via ICMP from node
network
interfaces: %(ping_scheme).
Check the cabling and VLAN
configuration within the cluster
nodes and Ethernet switches.
NAS upgrade services may stop
working properly. Migration of
resources across the cluster
may also be impacted. You may
be unable to perform software
upgrades.
https://www.dell.com/support/
article/SLN320935