Reference Guide
Table Of Contents
Alert and Event Messages
88 Dell EMC PowerStore Events and Alerts Reference Guide
Event code Severity Alert Call Home Message Repair Flow System Impact Knowledge Base Article
switch %(physical_switch_id),
with an MTU %(current_mtu)
that is too small.
0x01801701 INFO FALSE FALSE
MTU configuration on Ethernet
switch VLAN interface
corresponding to the intra-
cluster management (ICM)
network is correct.
- - -
0x01801702 MAJOR TRUE FALSE
Intra-cluster management (ICM)
network with VLAN
ID %(vlan_id) has corresponding
VLAN interface configured on
Ethernet
switch %(physical_switch_id),
with an MTU %(current_mtu)
that is too small.
Increase the MTU on VLAN
interface %(physical_switch_vla
n_iface_id) to at
least %(required_mtu).
-
https://www.dell.com/support/
article/SLN320925
0x01801801 INFO FALSE FALSE
MTU configuration on Ethernet
switch VLAN interface
corresponding to intra-cluster
data (ICD) network is correct.
- - -
0x01801802 MAJOR TRUE FALSE
Intra-cluster data (ICD) network
with VLAN ID %(vlan_id) has
corresponding VLAN interface
configured on Ethernet
switch %(physical_switch_id),
with an MTU %(current_mtu)
that is too small.
Increase the MTU on VLAN
interface %(physical_switch_vla
n_iface_id) to at
least %(required_mtu).
-
https://www.dell.com/support/
article/SLN320925
0x01801901 INFO FALSE FALSE
MTU configuration on Ethernet
switch VLAN interface
corresponding to storage
network is correct.
- - -
0x01801902 MAJOR TRUE FALSE
Storage network with VLAN
ID %(vlan_id) has corresponding
VLAN interface configured on
Ethernet
switch %(physical_switch_id),
with an MTU %(current_mtu)
that is too small.
Increase the MTU on VLAN
interface %(physical_switch_vla
n_iface_id) to at
least %(required_mtu).
-
https://www.dell.com/support/
article/SLN320925
0x01801A01 INFO FALSE FALSE
MTU configuration on Ethernet
switch VLAN interface
corresponding to the vMotion
network is correct.
- - -
0x01801A02 MAJOR TRUE FALSE
vMotion network with VLAN
ID %(vlan_id) has corresponding
VLAN interface configured on
Ethernet
Increase the MTU on VLAN
interface %(physical_switch_vla
n_iface_id) to at
least %(required_mtu).
-
https://www.dell.com/support/
article/SLN320925