Reference Guide
Table Of Contents
Alert and Event Messages
22 Dell EMC PowerStore Events and Alerts Reference Guide
Event code Severity Alert Call Home Message Repair Flow System Impact Knowledge Base Article
slot %(enclosure_slot) has not
completed successfully.
0x00306C01 INFO FALSE FALSE
Drive wear level (endurance) for
bus %(bus_num)
enclosure %(encl_num)
slot %(enclosure_slot) has
changed
to %(percent_endurance_remai
ning_level).
- - -
0x00306C02 MINOR TRUE TRUE
Wear level (endurance) of the
drive in bus %(bus_num)
enclosure %(encl_num)
slot %(enclosure_slot) is low.
The remaining wear level for
this drive
is %(percent_endurance_remai
ning)%.
Contact your service provider.
Drive will be used until the drive
fails or endurance is exhausted.
https://www.dell.com/support/
article/SLN317247
0x00306C03 MAJOR TRUE TRUE
Wear level (endurance) of the
drive in bus %(bus_num)
enclosure %(encl_num)
slot %(enclosure_slot) is very
low and has reached a critical
level. The remaining wear level
for this drive
is %(percent_endurance_remai
ning)%.
Contact your service provider.
Drive will be used until the drive
fails or endurance is exhausted.
https://www.dell.com/support/
article/SLN317247
0x00306C04 CRITICAL TRUE TRUE
Drive endurance level for
bus %(bus_num)
enclosure %(encl_num)
slot %(enclosure_slot) is
exhausted. The remaining wear
level for this drive
is %(percent_endurance_remai
ning)%.
Contact your service provider.
Drive will be used until the drive
fails.
https://www.dell.com/support/
article/SLN317247
0x00306D01 MINOR FALSE FALSE
Drive diagnostic state for
bus %(bus_num)
enclosure %(encl_num)
slot %(enclosure_slot) was
changed from %(old_value)
to %(diagnostic_health_state).
-
As long as all other drives are
healthy, and there still free
space to rebuild if another drive
fails the impact on cluster is
minimal. Cluster performance
may be impacted.
-
0x00306D02 MINOR TRUE TRUE
State of the drive in
bus %(bus_num)
enclosure %(encl_num)
slot %(enclosure_slot) cannot
-
As long as all other drives are
healthy, and there still free
space to rebuild if another drive
fails the impact on cluster is
-