Reference Guide

Alert and Event Messages
14 Dell EMC PowerStore Events and Alerts Reference Guide
Event code Severity Alert Call Home Message Repair Flow System Impact Knowledge Base Article
enclosure %(ssd_slot_array[].en
cl_num)
slot %(ssd_slot_array[].slot_nu
m) was changed
from %(old_value)
to %(ssd_slot_array[].slot_state)
.
0x00302002 MINOR FALSE FALSE
The slot state in
bus %(ssd_slot_array[].bus_nu
m)
enclosure %(ssd_slot_array[].en
cl_num)
slot %(ssd_slot_array[].slot_nu
m) was changed
from %(old_value)
to %(ssd_slot_array[].slot_state)
.
- - -
0x00302003 MINOR TRUE TRUE
Unsupported disk type or model
was detected in
slot %(ssd_slot_array[].slot_nu
m).
Replace the unsupported Drive.
Refer to the FRU Replacement
Procedures for details.
The Drive cannot be used by the
cluster.
-
0x00302004 MINOR TRUE TRUE
Uninitialized disk detected in
slot %(ssd_slot_array[].slot_nu
m).
Add the new Drive to the
cluster. Follow the Drive FRU
procedure.
Drive device cannot be used
until it is initialized.
-
0x00302005 MINOR TRUE TRUE
Foreign Drive from a different
Appliance or cluster detected in
slot %(ssd_slot_array[].slot_nu
m).
id=%(ssd_slot_array[].ssd_uid).
To use this Drive in this
Appliance follow the replacing
Drive procedure in the FRU
Replacement Procedures
document. Note that the data
will be ereased from the Drive.
Drive will not be used until
added to the cluster.
-
0x00302006 MAJOR TRUE TRUE
The state of
slot %(ssd_slot_array[].slot_nu
m) cannot be determined due
to an
error: %(ssd_slot_array[].slot_er
ror_reason).
-
Drive in this slot will not be
used. To keep the cluster in
optimal configuration this issue
should be promptly addressed.
https://www.dell.com/support/
article/SLN317225
0x00302501 NONE FALSE FALSE
D-modules are balanced on this
Node.
- - -
0x00302502 NONE FALSE FALSE
D-module had performed
failover. Failback is NOT allowed
at this time.
- - -
0x00302503 NONE FALSE FALSE
D-module had performed
failover. System is healthy and
has restarted D-module to
regain full SAS capacity.
- - -