Reference Guide

Alert and Event Messages
10 Dell EMC PowerStore Events and Alerts Reference Guide
Event code Severity Alert Call Home Message Repair Flow System Impact Knowledge Base Article
cabling-related alerts and take
necessary actions to resolve
such issues. If the condition
persists, contact your service
provider.
0x00201902 INFO FALSE FALSE Mapper metadata tier is online. - - -
0x00201A01 CRITICAL TRUE TRUE
Mapper Virtual Large Block
(VLB) tier is offline.
Check the cabling and
connections between the
nodes. Also, review any drive or
cabling-related alerts and take
necessary actions to resolve
such issues. If the condition
persists, contact your service
provider.
Read and write operations are
not available.
https://www.dell.com/support/
article/SLN317175
0x00201A02 INFO FALSE FALSE
Mapper Virtual Large Block
(VLB) tier is online.
- - -
0x00201B01 INFO FALSE FALSE
Appliance is going to run out of
storage space.
- - -
0x00201B02 INFO FALSE FALSE
Space utilization is below the
file system out-of-space
threshold.
- - -
0x00300301 NONE FALSE FALSE <No Message> - - -
0x00300401 INFO FALSE FALSE
Clear alerts for
object %(removed_object_nam
e) of
type %(removed_object_type).
- - -
0x00300B01 NONE FALSE FALSE
Cluster state was changed
from %(old_value)
to %(sys_health_state).
- - -
0x00300B02 MINOR FALSE FALSE
Cluster state was changed
from %(old_value)
to %(sys_health_state).
- - -
0x00300B03 MINOR FALSE FALSE
Cluster state was changed
from %(old_value)
to %(sys_health_state).
- - -
0x00300B04 MINOR FALSE FALSE
Cluster state was changed
from %(old_value)
to %(sys_health_state).
- - -
0x00300D01 MINOR FALSE FALSE
Cluster state was changed
from %(old_value)
to %(sys_state).
- - -
0x00300D02 MINOR FALSE FALSE
Cluster state was changed
from %(old_value)
to %(sys_state).
- - -