6 Known Issues
Issue ID Functional
Area
Description Workaround/Resolution
MDT-236192 Internal
Migration
Internal migration of imported volumes
from a remote system using the non-
disruptive import variant does not
redirect a host application running on
either Linux/Windows or VMware to
the associated PowerStore volumes.
To ensure a successful migration
between appliances for imported
volumes, reconfigure the host application
to PowerStore volume before initiating
intra-cluster migration.
MDT-167020
Internal
Migration
Migration of a storage resource failed
with the error "Transit object with
Handle <id> : status online on only one
node." One of the nodes of the
migration source appliance was down
when the synchronize phase started.
Both nodes must be online for
migration.
Bring the offline node back online and
then try the migration again.
MDT-145764 Internal
Migration
During migration the temporary
volumes that are created during
migration are calculated into the vVol
capacity metrics. The temporary
volumes should not be included in the
calculation.
Wait for migration to complete to get the
correct calculation.
MDT-140927
Internal
Migration
After a volume is migrated, there may
be a dip in capacity and performance
metrics reporting for that volume at
the end of the migration operation.
None
MDT-164726
Install or
Upgrade
If the Pre-Upgrade Health Check fails
during an upgrade from PowerStore
OS 1.0 to PowerStore OS 1.0.1 or later,
clicking the failed operation link under
Recent activities might result in an
error because of a localization issue
with the event message.
None
MDT-219735
Install or
Upgrade
If a PowerStore 1.0.3.0.5.007 software
upgrade package is uploaded to a
PowerStore T model cluster with a
single appliance running PowerStore
OS version 1.0.1.0.5.002 or
1.0.1.0.5.003, then an appliance running
PowerStore OS version 1.0.2.0.5.003 is
added to the cluster and another
PowerStore 1.0.3.0.5.007 software
upgrade package is uploaded to the
cluster, performing an upgrade will fail
before the upgrade process completes
on the primary appliance and the
second appliance will not be upgraded.
Contact your service provider.