Reference Guide

Alert and Event Messages
118 Dell EMC PowerStore Events and Alerts Reference Guide
Event Code Severity Alert Call Home Message Repair flow System impact Knowledge Base Article
0x01805D01 INFO FALSE FALSE
The vMotion TCP/IP stack
gateway is properly
configured on the ESXi
host %(host_name).
-
0x01805D02 MAJOR TRUE FALSE
The vMotion TCP/IP stack
gateway %(gateway) on
the ESXi host
%(host_name) is invalid.
The required gateway is
%(required_gateway).
Configure vMotion TCP/IP
stack gateway on the ESXi
host as shown.
https://dell.com/support/kbd
oc/000179613
0x01806401 INFO FALSE FALSE
MTU configuration on the
management VMkernel
adapter %(vmk_name) of
the ESXi host
%(host_name) is correct.
-
0x01806402 MINOR TRUE FALSE
Unable to obtain
information about MTU
configuration of the
management VMkernel
adapter %(vmk_name)
configured on the ESXi
host %(host_name).
Ensure that your vCenter is
healthy and reachable from
the management network.
Management functionality
with vCenter may be
impacted.
-
0x01806403 MAJOR TRUE TRUE
The management
VMkernel adapter
%(vmk_name) of the ESXi
host %(host_name) has an
invalid MTU
%(current_mtu).
Configure VMkernel
adapter with the required
MTU %(required_mtu).
Management functionality
with vCenter may be
impacted.
https://dell.com/support/kbd
oc/000179614
0x01806501 INFO FALSE FALSE
MTU configuration on the
vMotion VMkernel adapter
%(vmk_name) of the ESXi
host %(host_name) is
correct.
-
0x01806502 MINOR TRUE FALSE
Unable to obtain
information about MTU
configuration of the vMotion
VMkernel adapter
%(vmk_name) configured
on the ESXi host
%(host_name).
Ensure that your vCenter is
healthy and reachable from
the management network.
Management functionality
with vCenter may be
impacted.
-
0x01806503 MAJOR TRUE FALSE
The vMotion VMkernel
adapter %(vmk_name) of
the ESXi host
%(host_name) has an
invalid MTU
%(current_mtu).
Configure VMkernel
adapter with the required
MTU %(required_mtu).
Virtual volume migration
may be impacted.
https://dell.com/support/kbd
oc/000179615
0x01806601 INFO FALSE FALSE
MTU configuration on the
storage initiator VMkernel
adapter %(vmk_name) of
-