Users Guide

Table Of Contents
Configure an agentless import
Prerequisites
Ensure the following conditions exist on the PowerStore cluster before running import:
The global storage IP address for the PowerStore cluster is configured.
The PowerStore cluster and its nodes are in a healthy state.
Ensure that the following connections exist:
For either a Dell Compellent Storage Center (SC), Dell EMC VNX2 or Dell EMC Unity Series, or a Dell EMC XtremIO X1
or Dell EMC XtremIO X2 source system, a Fibre Channel (FC) or iSCSI connection between the source system and each
associated host system, and a matching FC or iSCSI connection between each associated host system and the PowerStore
cluster.
NOTE: These connections to each host system should be of the same type, either all FC or all iSCSI.
For a Dell EqualLogic Peer Storage (PS) Series source system, an iSCSI connection between the source system and each
associated host system, and a matching iSCSI connection between each associated host system and the PowerStore cluster.
For all source systems, only an iSCSI connection is supported between the source system and the PowerStore cluster.
It is recommended that the same NTP server is used on the source system, which hosts the source storage resource, and the
destination PowerStore cluster. This configuration should provide the proper time synchronization between the source system
and the destination PowerStore cluster.
Determine the following for the source system:
The type of source system for the import
(Applicable only to XtremIO X1 and XtremIO X2 systems) The name of the source system.
The management cluster IP address, which is one of the following:
For the Dell EqualLogic PS Series, it is the group management IP address, if the management network is configured.
Otherwise, it is the group IP address.
For the Dell Compellent SC Series and Dell EMC Unity Series systems, it is the management IP address of the system.
For Dell EMC VNX2 Series, it is the IP address of either SPA or SPB, however, the IP address of SPA is recommended.
For Dell EMC XtremIO X1 and Dell EMC XtremIO X2 systems, it is the IP address of the XMS.
The iSCSI IP address of the source system, which is one of the following:
For Dell EqualLogic PS Series, it is the group IP address.
For Dell Compellent SC Series, it is the IP address of the fault domain.
For Dell EMC VNX2 and Dell EMC Unity Series, and Dell EMC XtremIO X1 and Dell EMC XtremIO X2 source systems, it is
one of the IP addresses of the iSCSI front-end ports.
The administrative username and password credentials to access the source system
The session CHAP mode
The names of the volumes or consistency groups, or both
NOTE:
A volume group is automatically created for each consistency group that is selected for import. They cannot be
combined with any other volumes or volume group.
Which protection policy to use for the volume or volume group, or both.
Determine which hosts should be mapped to the PowerStore volumes.
Determine the schedule of the import:
Immediately or set a time and date
Whether to automatically cutover to the destination after import
Determine which protection policy to assign to the import volume.
About this task
To configure an import, do the following:
Steps
1. Log in to PowerStore Manager.
2. If the intended hosts associated with the import do not appear under Compute > Host & Host Groups, select Add Host as
needed and specify the relevant information for the hosts. Otherwise, go to the next step.
38