Owners Manual

Table 2. Embedded module LEDs (continued)
LED Location State Description
Port link Green Link up with high speed.
Amber Link up with degraded speed.
Off Link down.
Node fault Amber Fault has occurred in the node or one of
its components.
Off No fault has occurred. Normal operation.
Node power Green Node is on (main power).
Off Node is off.
Unsafe to remove White Do not remove the node. Improper
removal could cause data loss.
Off Safe to remove the node when the node
has been properly prepared.
Power down the node
Power down the node as described in Power control procedures.
Remove a faulted embedded module
Steps
1. Label and disconnect all cables that are attached to the embedded module.
CAUTION:
Do not pull the node from the base enclosure. Pulling the node from the base enclosure disrupts
the system cache.
2. Push the orange tab on the embedded module to release the lever.
Base enclosure service procedures
37