Reference Guide

Alert and Event Messages
64 Dell EMC PowerStore Events and Alerts Reference Guide
Event Code Severity Alert Call Home Message Repair flow System impact Knowledge Base Article
0x00A00402 MINOR TRUE FALSE
The cluster is projected to
run out of space in
%(ttf_days) days.
Consider performing one of
the following: add another
appliance or expansion
shelf, add drives, or remove
unused snapshots or
volumes.
Cluster is projected to run
out of capacity.
https://dell.com/support/kbd
oc/000131197
0x00A00403 INFO FALSE FALSE
Cluster is not projected to
run out of space for
%(ttf_days) days.
-
0x00A00501 INFO FALSE FALSE
VMware DRS service
configuration has been
recovered.
-
0x00A00502 MAJOR TRUE FALSE
Automated recovery of
vSphere DRS service
configuration has failed.
The current DRS
configuration is invalid.
The PowerStore X vSphere
cluster requires a DRS
automation level of Partially
Automated. Verify the DRS
settings and update if
necessary.
Some PowerStore X
clustering capabilities will
not be fully functional until
vSphere DRS settings are
updated.
https://dell.com/support/artic
le/SLN317189
0x00B00201 INFO FALSE FALSE
A new appliance has been
added.
-
0x00B00202 MAJOR TRUE FALSE
Appliance with DST:
%(serial_number) and IP
address: %(applianceIp)
failed to join cluster
%(clusterName).
Use the svc_factory_reset
script on the failed
appliance to return the
appliance to a factory state,
then retry the add appliance
operation. If the issue
persists, contact your
service provider.
Appliance could not be
added to the cluster.
https://dell.com/support/kbd
oc/000182004
0x00B00203 INFO FALSE FALSE
Add appliance post core
initialization started.
-
0x00B00301 INFO FALSE FALSE
CHAP mode has been
changed to disabled.
-
0x00B00302 INFO FALSE FALSE
CHAP mode has been
changed to single.
-
0x00B00303 INFO FALSE FALSE
CHAP mode has been
changed to mutual.
-
0x00B00401 INFO FALSE FALSE
An appliance is being
removed from cluster.
-
0x00B00402 INFO FALSE FALSE
An appliance has been
removed from cluster.
-
0x00B00403 MINOR FALSE FALSE
Appliance removal
validation has failed.
Resolve the blocking errors
and try again.
Appliance cannot be
removed.
-
0x00B00404 MAJOR TRUE FALSE
Appliance removal has
failed.
Retry the appliance
removal. If the problem
Appliance cannot be
removed.
https://dell.com/support/kbd
oc/000182004