Event Code Severity Alert Call Home Message Repair flow System impact Knowledge Base Article
0x01803A03 MAJOR TRUE FALSE
The switch has inter-
chassis link (ICL) protocol
errors.
Ensure that an inter-chassis
link (ICL) is properly
configured between the
switches.
Network high availability or
performance may be
degraded.
https://dell.com/support/kbd
oc/000179606
0x01803B01 INFO FALSE FALSE
The Distributed Virtual
Switch %(dvs_name) is
configured in the vCenter.
-
0x01803B02 MAJOR TRUE FALSE
Unable to find the
Distributed Virtual Switch
with the name
%(dvs_name) in vCenter.
Ensure that a Distributed
Virtual Switch is configured
in vCenter based on the
information provided during
initial configuration or
contact your service
provider.
Any network-specific
operation may be
impacted.
https://dell.com/support/kbd
oc/000179607
0x01803C01 INFO FALSE FALSE
Physical MTU configuration
on the Distributed Virtual
Switch %(dvs_name) is
correct.
-
0x01803C02 MINOR FALSE FALSE
Unable to obtain physical
MTU configuration for the
Distributed Virtual Switch
%(dvs_name).
-
0x01803C03 MAJOR TRUE FALSE
Physical MTU on the
Distributed Virtual Switch
%(dvs_name) has an
invalid value
%(current_mtu). The
required MTU is
%(required_mtu).
Change the physical MTU
settings on the Distributed
Virtual Switch.
https://dell.com/support/kbd
oc/000179607
0x01803D01 INFO FALSE FALSE
The version of the
Distributed Virtual Switch
%(dvs_name) matches the
system requirements.
-
0x01803D02 MINOR FALSE FALSE
Unable to obtain
information on the version
of the Distributed Virtual
Switch %(dvs_name).
-
0x01803D03 MAJOR TRUE FALSE
The version of the
Distributed Virtual Switch
%(dvs_name) does not
match to %(dvs_version)
which is required by the
system.
Configure the Distributed
Virtual Switch in vCenter
based on the system
requirements described in
the Virtualization with
PowerStore Guide. If the
issue persists, contact your
service provider.
https://dell.com/support/kbd
oc/000179608
0x01803E01 INFO FALSE FALSE
The system VM
management port group
%(pg_name) is configured
-