Reference Guide

Alert and Event Messages
37 Dell EMC PowerStore Events and Alerts Reference Guide
Event code Severity Alert Call Home Message Repair Flow System Impact Knowledge Base Article
Installation and Service Guide
for more information.
0x00309205 NONE FALSE FALSE
Component lifecycle state has
changed.
- - -
0x00309206 NONE FALSE FALSE
Component lifecycle state has
changed.
- - -
0x00309207 NONE FALSE FALSE
Component lifecycle state has
changed.
- - -
0x00309208 INFO FALSE FALSE
Component lifecycle state has
changed.
No action is required. - -
0x00309301 NONE FALSE FALSE
Node's fan module enabled
state has changed.
- - -
0x00309302 NONE FALSE FALSE
Node's fan module enabled
state has changed.
- - -
0x00309303 NONE FALSE FALSE
The node's fan module has been
disabled.
- - -
0x00309401 NONE FALSE FALSE
Node's fan module lifecycle
state has changed.
- - -
0x00309402 NONE FALSE FALSE Node's fan module is initializing. - - -
0x00309403 MAJOR TRUE TRUE Node's fan module has faulted.
Replace the fan module. Refer
to the Installation and Service
Guide for more information.
System cooling may be
degraded.
https://www.dell.com/support/
article/SLN317235
0x00309404 MINOR TRUE FALSE
Node's fan module is
disconnected.
Try reseating the fan power
cable. If the issue persists,
replace the fan module. Refer
to the Installation and Service
Guide for more information.
System cooling may be
degraded.
-
0x00309405 NONE FALSE FALSE
Node's fan module is not
initialized.
- - -
0x00309406 NONE FALSE FALSE
Node's fan module lifecycle
state has changed.
- - -
0x00309407 NONE FALSE FALSE
Node's fan module lifecycle
state has changed.
- - -
0x00309501 NONE FALSE FALSE
Node's DIMM lifecycle state has
changed.
- - -
0x00309502 NONE FALSE FALSE Node's DIMM is initializing. - - -
0x00309503 MAJOR TRUE TRUE Node's DIMM has faulted.
Replace the DIMM. Refer to the
Installation and Service Guide
for more information.
Performance may be degraded.
https://www.dell.com/support/
article/SLN317227
0x00309504 MAJOR TRUE FALSE Node's DIMM is disconnected.
Try reseating the DIMM. If the
issue persists, replace the
DIMM. Refer to the Installation
and Service Guide for more
information.
Performance may be degraded.
https://www.dell.com/support/
article/SLN317227