Reference Guide

Alert and Event Messages
89 Dell EMC PowerStore Events and Alerts Reference Guide
Event code
Severity
Alert raised
Call home
Repair flow
System impact
Knowledge Base Article
%(physical_switch_id).
connecting this port to an
out of band management
switch.
0x01800801 INFO FALSE FALSE
properly to the Ethernet
- - -
0x01800802 MAJOR TRUE FALSE
the out of band
management switch:
Check cabling of the node
and connect these ports to
the main Ethernet switches.
Performance or
connectivity may be
degraded.
https://www.dell.com/support
/Article/SLN317215
0x01800901 INFO FALSE FALSE
connected to different
- - -
0x01800902 MAJOR TRUE FALSE
Node ports are connected
to the same Ethernet
switch:
%(connection_scheme).
Check cabling of the node
and ensure that the ports
are connected to different
switches to avoid a single
point of failure.
-
https://www.dell.com/support
/Article/SLN317215
0x01800A01 INFO FALSE FALSE
- - -
0x01800A02 MAJOR TRUE FALSE
Order of node port cabling
is not correct:
%(connection_scheme).
Check cabling of the node
and ensure that the ports
are connected to different
Ethernet switches in
alternating fashion to
ensure high network
availability.
-
https://www.dell.com/support
/Article/SLN317215
0x01800B01 INFO FALSE FALSE
properly connected to
- - -
0x01800B02 MAJOR TRUE FALSE
Partner data ports are
connected to the same
physical switch:
%(connection_scheme).
Check the cabling of the
appliance and ensure that
data ports of each node are
connected to different
physical switches to avoid a
single point of failure.
- https://www.dell.com/support
0x01800C01 INFO FALSE FALSE
connected to Ethernet
switches of the same
- - -
0x01800C02 MINOR FALSE FALSE
- - -
0x01800C03 MAJOR TRUE FALSE
Ethernet switches of
different models:
%(physical_switch_models)
It is recommended that you
use the same Ethernet
switch models with an
appliance.
- https://www.dell.com/support
0x01800D01 INFO FALSE FALSE
- - -